Skip to main content
Window · Vinyl Frame NFRC TTW · Product Line TTW-A-10

Thermo-Tech Windows — 7600 Double Hung · Double Hung

Across 8 Thermo-Tech Windows certified families, 7600 Double Hung supplies 404 Double Hung configurations starting at 0.24 U-Factor and 0.15 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.31 U-Factor and 0.47 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.15-0.47
Certified Options
404
Category Standing
#1,034 of 1,352

How does Thermo-Tech Windows 7600 Double Hung compare thermally against Window peers?

Thermo-Tech Windows 7600 Double Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 7600 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 7600 Double Hung (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

7600 Double Hung Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 7600 Double Hung is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.31.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 16 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors TTW to 2024-02-10 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 404 certified glazing combinations for 7600 Double Hung (NFRC TTW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 16 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 42 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 116 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 373 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Westlake Royal Windows LLC — 700 Single Hung Vinyl 0.24 0.16 405
Quaker Window Products — V100 Horizontal Slider Vinyl 0.24 0.14 410
Quaker Window Products — V100 Single Hung Vinyl 0.24 0.14 398
MGM Industries — 6010 Horizontal Slider Vinyl 0.24 0.13 382
JELD-WEN, inc. — Premium Altantic Vinyl Horizontal Slider Vinyl 0.24 0.13 429

What other certified series does Thermo-Tech Windows produce?

Compare other active Thermo-Tech Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thermo-Tech Windows 7600 Double Hung appear below.

What U-Factor and SHGC range does Thermo-Tech Windows 7600 Double Hung achieve?

Testing puts Thermo-Tech Windows 7600 Double Hung at rank #1,034 of 1,352 Window entries with U 0.24 to 0.31 across 404 configurations. Solar heat gain ranges between 0.15 and 0.47 across Northern, North-Central, South-Central, Southern.

Does Thermo-Tech Windows 7600 Double Hung qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern approval ends at U <= 0.22, above 7600 Double Hung's 0.24 minimum. However, 16 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

What BTU/hr heat transfer results from 7600 Double Hung's 0.24 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.24 U-Factor yields 144.0 BTU/hr conductive transfer (+9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose Thermo-Tech Windows 7600 Double Hung for a residential project?

Do not specify 7600 Double Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 7600 Double Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many 7600 Double Hung glazing packages pass Southern solar-heat rules?

Exactly 373 7600 Double Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.47 glass.

Does 7600 Double Hung carry EPA Most Efficient certification across its lineup?

7600 Double Hung holds zero Most Efficient entries across its 404 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

What federal compliance checks govern 2026 7600 Double Hung window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 7600 Double Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

What permanent glass etch marks verify 7600 Double Hung after sticker removal?

Match the NFRC thermal sticker for code TTW and line TTW-A-10 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Thermo-Tech Windows 7600 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros