Skip to main content
Window · Vinyl Frame NFRC MGM · Product Line MGM-A-32

MGM Industries — 6010 Horizontal Slider · Single Slider

Positioning #1,034/1,352 in certified Window, MGM Industries 6010 Horizontal Slider pairs Vinyl frame construction with 382 glazing options rated between 0.13 and 0.28 SHGC across North-Central, South-Central, Southern. Across 7 certified MGM Industries product families, its thermal resistance spans 0.24 to 0.31 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.24
SHGC Range
0.13-0.28
Certified Options
382
Category Standing
#1,034 of 1,352

How does MGM Industries 6010 Horizontal Slider compare thermally against Window peers?

MGM Industries 6010 Horizontal Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 6010 Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 6010 Horizontal Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

6010 Horizontal Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places MGM Industries 6010 Horizontal Slider at rank #1,034 of 1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.13-0.28 band.

Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2018-11-08 and v7.0 data certification on 2026-04-29. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 382 certified glazing combinations for 6010 Horizontal Slider (NFRC MGM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 65 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 194 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 368 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Westlake Royal Windows LLC — 250 Single Hung Vinyl 0.24 0.17 376
EnergyWall Window — 3030 Slider Vinyl 0.24 0.19 373
Polaris Windows and Doors — 3030 Slider Vinyl 0.24 0.19 373
Quaker Window Products — V100 Single Hung Vinyl 0.24 0.14 398
Thermo-Tech Windows — 7600 Double Hung Vinyl 0.24 0.15 404

What other certified series does MGM Industries produce?

Compare other active MGM Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MGM Industries 6010 Horizontal Slider appear below.

How efficient is MGM Industries 6010 Horizontal Slider compared with peer Window models?

Testing puts MGM Industries 6010 Horizontal Slider at rank #1,034 of 1,352 Window entries with U 0.24 to 0.31 across 382 configurations. Solar heat gain ranges between 0.13 and 0.28 across North-Central, South-Central, Southern.

Can homeowners install 6010 Horizontal Slider in cold Northern ENERGY STAR counties?

No. Because 6010 Horizontal Slider reaches only 0.24 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Vinyl line strictly across North-Central, South-Central, Southern cooling or mixed markets.

How much winter heat loss does 6010 Horizontal Slider conduct across a 15 sq ft opening?

Using NFRC MGM U-Factor 0.24, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 144.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+12.0 BTU/hr margin).

Which situations make 6010 Horizontal Slider the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 6010 Horizontal Slider options exceeding U 0.22. Additionally, do not order Horizontal Slider (HSOX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in 6010 Horizontal Slider?

Across North-Central, South-Central, Southern, 368 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside MGM Industries 6010 Horizontal Slider, while total line SHGC reaches 0.28 in colder packages.

What glazing share inside 6010 Horizontal Slider qualifies as Most Efficient?

6010 Horizontal Slider holds zero Most Efficient entries across its 382 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

How do the 25C sunset and pre-1978 Lead RRP rules affect 6010 Horizontal Slider?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 6010 Horizontal Slider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on 6010 Horizontal Slider?

Confirm both the paper NFRC label and permanent corner glass etch match line MGM-A-32 and NFRC ID MGM before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MGM Industries 6010 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)