Skip to main content
Window · Vinyl Frame NFRC EWW · Product Line EWW-M-4

EnergyWall Window — 3030 Slider · Double Slider

Across 10 EnergyWall Window certified families, 3030 Slider supplies 373 Double Slider configurations starting at 0.24 U-Factor and 0.19 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.51 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.19-0.51
Certified Options
373
Category Standing
#1,034 of 1,352

How does EnergyWall Window 3030 Slider compare thermally against Window peers?

EnergyWall Window 3030 Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 3030 SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 3030 Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

3030 Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 3030 Slider spans 373 NFRC test records (EWW), ranking #1,034 of 1,352 Window families (tied with 139 others at 0.24, more insulating than 13.2% of Window lines). Its 0.24 thermal floor compares at +0.05 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.19 to 0.51) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 138 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-08-01 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 373 certified glazing combinations for 3030 Slider (NFRC EWW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 138 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 3 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 184 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 235 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Polaris Windows and Doors — 3030 Slider Vinyl 0.24 0.19 373
Westlake Royal Windows LLC — 250 Single Hung Vinyl 0.24 0.17 376
MGM Industries — 6010 Horizontal Slider Vinyl 0.24 0.13 382
Quaker Window Products — V100 Single Hung Vinyl 0.24 0.14 398
Thermo-Tech Windows — 7600 Double Hung Vinyl 0.24 0.15 404

What other certified series does EnergyWall Window produce?

Compare other active EnergyWall Window certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to EnergyWall Window 3030 Slider appear below.

What thermal performance numbers separate EnergyWall Window 3030 Slider from peers?

EnergyWall Window 3030 Slider spans 373 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.19 to 0.51. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

Is 3030 Slider approved for Northern Zone heating climates?

Northern qualification on 3030 Slider relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 138 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

What conductive BTU/hr difference separates 3030 Slider from the 0.22 Northern rule?

Using NFRC EWW U-Factor 0.24, a 15 sq ft Dual-Slide Horizontal (HSXX) assembly conducts 144.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+12.0 BTU/hr margin).

Which situations make 3030 Slider the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 3030 Slider options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install EnergyWall Window 3030 Slider in Southern or South-Central zones?

Yes, 3030 Slider holds 235 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.19 SHGC in cooling climates.

How many EnergyWall Window 3030 Slider variants earn ENERGY STAR Most Efficient?

All 373 3030 Slider listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Can homeowners claim Form 5695 credits on EnergyWall Window 3030 Slider in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 EnergyWall Window upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC EWW and product line EWW-M-4 on delivery?

Match the NFRC thermal sticker for code EWW and line EWW-M-4 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for EnergyWall Window 3030 Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros