Skip to main content
Window · Vinyl Frame NFRC MGM · Product Line MGM-A-21 ENERGY STAR Most Efficient Eligible

MGM Industries — 4600 Picture Window / Transom · Picture Window

MGM Industries engineered the 4600 Picture Window / Transom Picture Window line for Northern, North-Central, South-Central, Southern, certifying 57 glass-spacer combinations from 0.21 to 0.30 U-Factor and 0.19 to 0.32 SHGC. Relative to other Vinyl models tracked under NFRC MGM, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.21
SHGC Range
0.19-0.32
Certified Options
57
Category Standing
#742 of 1,352

How does MGM Industries 4600 Picture Window / Transom compare thermally against Window peers?

MGM Industries 4600 Picture Window / Transom achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 4600 Picture Window / TransomHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 4600 Picture Window / Transom (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

4600 Picture Window / Transom Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 4600 Picture Window / Transom is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.21-0.30.

Mapping NFRC SHGC values (0.19 to 0.32) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 13 configurations meet ENERGY STAR Most Efficient criteria while 30 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-11-08 and cert timestamp 2024-04-12.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 57 certified glazing combinations for 4600 Picture Window / Transom (NFRC MGM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 30 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 45 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 31 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 35 packages (13 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Wallside Windows — ESTDS Double Slider Vinyl 0.21 0.18 64
Vytex Corporation — Fortis Double Hung Vinyl 0.21 0.16 68
Wallside Windows — SDH Double Hung Vinyl 0.21 0.18 72
Vinyl Kraft, Inc. — TrustGard Horizontal Slider Vinyl 0.21 0.17 76
Vytex Corporation — 8000 Fixed Vinyl 0.21 0.21 36

What other certified series does MGM Industries produce?

Compare other active MGM Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MGM Industries 4600 Picture Window / Transom appear below.

Where does MGM Industries 4600 Picture Window / Transom stand thermally among ENERGY STAR Window lines?

Across 57 tested NFRC glazing configurations, MGM Industries 4600 Picture Window / Transom with Vinyl framing and Fixed Window (FIXD) style reaches a 0.21 minimum U-Factor and 0.19-0.32 SHGC band. It places #742 among 1,352 Window series—more insulating than 38.6%.

Can homeowners install 4600 Picture Window / Transom in cold Northern ENERGY STAR counties?

Cold-climate buyers get 30 compliant Northern packages inside 4600 Picture Window / Transom, reaching down to U 0.21. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.30 options.

What conductive BTU/hr difference separates 4600 Picture Window / Transom from the 0.22 Northern rule?

At U 0.21, a standard 3x5 ft (15 sq ft) 4600 Picture Window / Transom opening transfers 126.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -6.0 BTU/hr difference.

Which situations make 4600 Picture Window / Transom the wrong window or door choice?

Do not specify 4600 Picture Window / Transom without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 4600 Picture Window / Transom options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

What Southern ENERGY STAR v7.0 options exist in 4600 Picture Window / Transom?

Warm-climate homeowners have 35 Southern-approved options within 4600 Picture Window / Transom spanning SHGC down to 0.19. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside 4600 Picture Window / Transom qualifies as Most Efficient?

Only 13 options out of 57 (22.8%) meet tighter Most Efficient U-Factor and SHGC thresholds in MGM Industries 4600 Picture Window / Transom, usually requiring triple-pane or upgraded Low-E coatings.

What federal compliance checks govern 2026 4600 Picture Window / Transom window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on 4600 Picture Window / Transom?

Inspectors match the temporary NFRC sticker (U 0.21-0.30, SHGC 0.19-0.32) against permit drawings for line MGM-A-21. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MGM Industries 4600 Picture Window / Transom come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros