Wallside Windows — ESTDS Double Slider · Double Slider
Wallside Windows ESTDS Double Slider is a Double Slider assembly with a Vinyl frame that reaches a minimum U-Factor of 0.21 across 64 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #742 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.18 to 0.48.
- Min U-Factor
- 0.21
- SHGC Range
- 0.18-0.48
- Certified Options
- 64
- Category Standing
- #742 of 1,352
How does Wallside Windows ESTDS Double Slider compare thermally against Window peers?
Wallside Windows ESTDS Double Slider achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 7 certified Wallside Windows series, this Double Slider offers a 0.07 U-Factor adjustment span between 0.28 entry options and 0.21 top-performing glazing. Category standing is #742/1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines).
Mapping NFRC SHGC values (0.18 to 0.48) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 2 configurations meet ENERGY STAR Most Efficient criteria while 25 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2024-11-15 and FENSTAR license 2018-08-23 inside EPA Version 7.0 tables. Heat transfer computes to 126.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 64 certified glazing combinations for ESTDS Double Slider (NFRC WAW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 25 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 36 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 38 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 38 packages (2 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Vytex Corporation — Fortis Double Hung | Vinyl | 0.21 | 0.16 | 68 |
| MGM Industries — 4600 Picture Window / Transom | Vinyl | 0.21 | 0.19 | 57 |
| Vinyl Kraft, Inc. — TrustGard Horizontal Slider | Vinyl | 0.21 | 0.17 | 76 |
| United Window & Door Mfg., Inc. — 9640 Picture Window | Vinyl | 0.21 | 0.17 | 81 |
| Vytex Corporation — 8000 Fixed | Vinyl | 0.21 | 0.21 | 36 |
What other certified series does Wallside Windows produce?
Compare other active Wallside Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
PD2 Patio Door (Exterior Glazed)
U-Factor 0.22–0.28 · 42 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wallside Windows ESTDS Double Slider appear below.
How efficient is Wallside Windows ESTDS Double Slider compared with peer Window models?
Wallside Windows ESTDS Double Slider spans 64 certified configurations with U-Factors between 0.21 and 0.28 and SHGC values from 0.18 to 0.48. Ranked #742 of 1,352 Window families, it carries 2 Most Efficient options.
Is ESTDS Double Slider approved for Northern Zone heating climates?
Wallside Windows ESTDS Double Slider supplies 25 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.
What BTU/hr heat transfer results from ESTDS Double Slider's 0.21 minimum U-Factor?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 126.0 BTU/hr on ESTDS Double Slider's lowest-U package (0.21), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.
Which situations make ESTDS Double Slider the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on ESTDS Double Slider options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
What Southern ENERGY STAR v7.0 options exist in ESTDS Double Slider?
Across Northern, North-Central, South-Central, Southern, 38 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Wallside Windows ESTDS Double Slider, while total line SHGC reaches 0.48 in colder packages.
What glazing share inside ESTDS Double Slider qualifies as Most Efficient?
Only 2 options out of 64 (3.1%) meet tighter Most Efficient U-Factor and SHGC thresholds in Wallside Windows ESTDS Double Slider, usually requiring triple-pane or upgraded Low-E coatings.
What 2026 federal tax credit and Lead RRP rules apply to ESTDS Double Slider?
Any ESTDS Double Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How do building inspectors verify ESTDS Double Slider glass specs on job sites?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code WAW and product line WAW-K-15, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Wallside Windows ESTDS Double Slider come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)