Skip to main content
Door · Vinyl Frame NFRC WAW · Product Line WAW-K-13

Wallside Windows — PD2 Patio Door (Exterior Glazed) · Sliding Patio Door

Positioning #145/268 in certified Door, Wallside Windows PD2 Patio Door (Exterior Glazed) pairs Vinyl frame construction with 42 glazing options rated between 0.19 and 0.29 SHGC across Northern, North-Central, South-Central, Southern. Across 7 certified Wallside Windows product families, its thermal resistance spans 0.22 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.22
SHGC Range
0.19-0.29
Certified Options
42
Category Standing
#145 of 268

How does Wallside Windows PD2 Patio Door (Exterior Glazed) compare thermally against Door peers?

Wallside Windows PD2 Patio Door (Exterior Glazed) achieves a 0.22 thermal floor across Door lines, placing #145 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. PD2 Patio Door (Exterior Glazed)Histogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing PD2 Patio Door (Exterior Glazed) (U 0.22).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.22430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

PD2 Patio Door (Exterior Glazed) Cohort StandingMin U-Factor 0.22 stands at rank #145 of 268, outperforming 39.9% of peers.Min U-Factor 0.22Rank #145 of 268 (39.9% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), PD2 Patio Door (Exterior Glazed) is 0.01 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.22-0.28.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 24 combinations qualify in the Northern Zone alongside 22 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.22 U-Factor yields 132.0 BTU/hr transfer (matching the 0.22 Northern baseline). Manufacturer filing reflects 2018-08-23 licensing and 2025-06-13 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 42 certified glazing combinations for PD2 Patio Door (Exterior Glazed) (NFRC WAW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 24 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 24 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 22 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 22 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Wallside Windows produce?

Compare other active Wallside Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wallside Windows PD2 Patio Door (Exterior Glazed) appear below.

How well does PD2 Patio Door (Exterior Glazed) by Wallside Windows insulate relative to Door benchmarks?

Across 42 tested NFRC glazing configurations, Wallside Windows PD2 Patio Door (Exterior Glazed) with Vinyl framing and Sliding Glass Door (DDSG) style reaches a 0.22 minimum U-Factor and 0.19-0.29 SHGC band. It places #145 among 268 Door series—more insulating than 39.9%.

How does Wallside Windows PD2 Patio Door (Exterior Glazed) satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 24 compliant Northern packages inside PD2 Patio Door (Exterior Glazed), reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

How much winter heat loss does PD2 Patio Door (Exterior Glazed) conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 132.0 BTU/hr on PD2 Patio Door (Exterior Glazed)'s lowest-U package (0.22), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

When should a buyer skip Wallside Windows PD2 Patio Door (Exterior Glazed) and compare alternatives?

Skip PD2 Patio Door (Exterior Glazed) if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on PD2 Patio Door (Exterior Glazed) options exceeding U 0.22.

How many PD2 Patio Door (Exterior Glazed) glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 22 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Wallside Windows PD2 Patio Door (Exterior Glazed), while total line SHGC reaches 0.29 in colder packages.

What glazing share inside PD2 Patio Door (Exterior Glazed) qualifies as Most Efficient?

Zero glazing builds inside PD2 Patio Door (Exterior Glazed)'s 42 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What federal compliance checks govern 2026 PD2 Patio Door (Exterior Glazed) window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify PD2 Patio Door (Exterior Glazed) glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.22-0.28, SHGC 0.19-0.29) against permit drawings for line WAW-K-13. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wallside Windows PD2 Patio Door (Exterior Glazed) come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros