Door · Vinyl Frame NFRC PHC · Product Line PHC-K-5 ENERGY STAR Most Efficient Eligible

P H Tech Corp — S-7500 Patio Door · Sliding Patio Door

Positioning #145/268 in certified Door, P H Tech Corp S-7500 Patio Door pairs Vinyl frame construction with 79 glazing options rated between 0.05 and 0.32 SHGC across Northern, North-Central, South-Central, Southern. Across 2 certified P H Tech Corp product families, its thermal resistance spans 0.22 to 0.28 U-Factor and the line includes 1 ENERGY STAR Most Efficient package (1.3% of line).

Min U-Factor
0.22
SHGC Range
0.05-0.32
Certified Options
79
Category Standing
#145 of 268

How does P H Tech Corp S-7500 Patio Door compare thermally against Door peers?

P H Tech Corp S-7500 Patio Door achieves a 0.22 thermal floor across Door lines, placing #145 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. S-7500 Patio DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing S-7500 Patio Door (U 0.22).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.22430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

S-7500 Patio Door Cohort StandingMin U-Factor 0.22 stands at rank #145 of 268, outperforming 39.9% of peers.Min U-Factor 0.22Rank #145 of 268 (39.9% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows P H Tech Corp S-7500 Patio Door standing at #145 of 268 certified Door product series, tied with 16 others at 0.22, more insulating than 39.9% of Door lines. Comparing Vinyl profiles alone (median 0.19) shows +0.03 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. 1 configuration meet ENERGY STAR Most Efficient criteria while 50 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 132.0 BTU/hr (equal to the 0.22 Northern floor). Records show license timestamp 2018-10-03 and cert timestamp 2024-07-03.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 79 certified glazing combinations for S-7500 Patio Door (NFRC PHC) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 50 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 50 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 68 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 68 packages (1 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does P H Tech Corp produce?

Compare other active P H Tech Corp certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to P H Tech Corp S-7500 Patio Door appear below.

Where does P H Tech Corp S-7500 Patio Door stand thermally among ENERGY STAR Door lines?

EPA ENERGY STAR v7.0 records 79 configurations for P H Tech Corp S-7500 Patio Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.22 versus a 0.21 Door median. Only 1 option earn Most Efficient status.

How does P H Tech Corp S-7500 Patio Door satisfy Version 7.0 Northern criteria?

Yes, 50 packages satisfy Northern ENERGY STAR Version 7.0 rules in S-7500 Patio Door. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How does a 3x5 ft S-7500 Patio Door window perform under a 40 deg F temperature drop?

Using NFRC PHC U-Factor 0.22, a 15 sq ft Sliding Glass Door (DDSG) assembly conducts 132.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+0.0 BTU/hr margin).

What homeowner profiles are a poor match for P H Tech Corp S-7500 Patio Door?

Cold-climate owners needing prescriptive U <= 0.22 should pass on S-7500 Patio Door options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install P H Tech Corp S-7500 Patio Door in Southern or South-Central zones?

Yes, S-7500 Patio Door holds 68 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.05 SHGC in cooling climates.

Does S-7500 Patio Door carry EPA Most Efficient certification across its lineup?

EPA lists 1 Most Efficient option (1.3% share) inside P H Tech Corp S-7500 Patio Door, out of 79 total Version 7.0 entries.

Do 2026 S-7500 Patio Door installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 S-7500 Patio Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered P H Tech Corp S-7500 Patio Door units match permits?

Match the NFRC thermal sticker for code PHC and line PHC-K-5 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for P H Tech Corp S-7500 Patio Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros