Window · Vinyl Frame NFRC WAW · Product Line WAW-K-22 ENERGY STAR Most Efficient Eligible

Wallside Windows — SC-V Casement · Casement Windows

Positioning #564/1,352 in certified Window, Wallside Windows SC-V Casement pairs Vinyl frame construction with 56 glazing options rated between 0.16 and 0.42 SHGC across Northern, North-Central, South-Central, Southern. Across 7 certified Wallside Windows product families, its thermal resistance spans 0.19 to 0.26 U-Factor and the line includes 18 ENERGY STAR Most Efficient packages (32.1% of line).

Min U-Factor
0.19
SHGC Range
0.16-0.42
Certified Options
56
Category Standing
#564 of 1,352

How does Wallside Windows SC-V Casement compare thermally against Window peers?

Wallside Windows SC-V Casement achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. SC-V CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing SC-V Casement (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

SC-V Casement Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), SC-V Casement reaches 0.19 on its lowest-conductivity package — #429 of 1,009 in Vinyl, tied with 83 others at 0.19, more insulating than 49.3% of Vinyl lines (At median vs Vinyl peers). Pairing NFRC ID WAW across multi-pane fills shifts U-Factor from 0.26 down toward 0.19.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 18 configurations meet ENERGY STAR Most Efficient criteria while 40 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.19 U-Factor yields 114.0 BTU/hr transfer (-18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-08-23 licensing and 2024-11-15 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 56 certified glazing combinations for SC-V Casement (NFRC WAW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 40 packages (9 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 46 packages (13 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 38 packages (13 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 38 packages (18 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Soft-Lite, LLC — Elements DH20 Double Hung Vinyl 0.19 0.16 68
Soft-Lite, LLC — Imperial Elite DH12E Vinyl 0.19 0.16 68
Vinyl Kraft, Inc. — 2000/2500 Single Hung Vinyl 0.19 0.17 68
Northeast Building Products Corporation — Elite DH PW Vinyl 0.19 0.17 76
Northeast Building Products Corporation — Elite NC PW Vinyl 0.19 0.16 77

What other certified series does Wallside Windows produce?

Compare other active Wallside Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wallside Windows SC-V Casement appear below.

What U-Factor and SHGC range does Wallside Windows SC-V Casement achieve?

Testing puts Wallside Windows SC-V Casement at rank #564 of 1,352 Window entries with U 0.19 to 0.26 across 56 configurations. Solar heat gain ranges between 0.16 and 0.42 across Northern, North-Central, South-Central, Southern.

Is SC-V Casement approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 40 SC-V Casement packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.26, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates SC-V Casement from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), SC-V Casement at U 0.19 conducts 114.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying SC-V Casement?

Cold-climate owners needing prescriptive U <= 0.22 should pass on SC-V Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Wallside Windows SC-V Casement in Southern or South-Central zones?

Yes. 38 Southern-certified options inside Wallside Windows SC-V Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.42 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside SC-V Casement qualifies as Most Efficient?

No. Exactly 18 of 56 configurations (32.1%) earn ENERGY STAR Most Efficient status in SC-V Casement; the remaining standard v7.0 options pass base zone limits only.

Can homeowners claim Form 5695 credits on Wallside Windows SC-V Casement in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Wallside Windows upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify SC-V Casement glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line WAW-K-22 and NFRC ID WAW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wallside Windows SC-V Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros