Wallside Windows — SC-V Casement · Casement Windows
Positioning #564/1,352 in certified Window, Wallside Windows SC-V Casement pairs Vinyl frame construction with 56 glazing options rated between 0.16 and 0.42 SHGC across Northern, North-Central, South-Central, Southern. Across 7 certified Wallside Windows product families, its thermal resistance spans 0.19 to 0.26 U-Factor and the line includes 18 ENERGY STAR Most Efficient packages (32.1% of line).
- Min U-Factor
- 0.19
- SHGC Range
- 0.16-0.42
- Certified Options
- 56
- Category Standing
- #564 of 1,352
How does Wallside Windows SC-V Casement compare thermally against Window peers?
Wallside Windows SC-V Casement achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Vinyl cohort (0.19 median U-Factor), SC-V Casement reaches 0.19 on its lowest-conductivity package — #429 of 1,009 in Vinyl, tied with 83 others at 0.19, more insulating than 49.3% of Vinyl lines (At median vs Vinyl peers). Pairing NFRC ID WAW across multi-pane fills shifts U-Factor from 0.26 down toward 0.19.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 18 configurations meet ENERGY STAR Most Efficient criteria while 40 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.19 U-Factor yields 114.0 BTU/hr transfer (-18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-08-23 licensing and 2024-11-15 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 56 certified glazing combinations for SC-V Casement (NFRC WAW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 40 packages (9 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 46 packages (13 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 38 packages (13 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 38 packages (18 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Soft-Lite, LLC — Elements DH20 Double Hung | Vinyl | 0.19 | 0.16 | 68 |
| Soft-Lite, LLC — Imperial Elite DH12E | Vinyl | 0.19 | 0.16 | 68 |
| Vinyl Kraft, Inc. — 2000/2500 Single Hung | Vinyl | 0.19 | 0.17 | 68 |
| Northeast Building Products Corporation — Elite DH PW | Vinyl | 0.19 | 0.17 | 76 |
| Northeast Building Products Corporation — Elite NC PW | Vinyl | 0.19 | 0.16 | 77 |
What other certified series does Wallside Windows produce?
Compare other active Wallside Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
PD2 Patio Door (Exterior Glazed)
U-Factor 0.22–0.28 · 42 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wallside Windows SC-V Casement appear below.
What U-Factor and SHGC range does Wallside Windows SC-V Casement achieve?
Testing puts Wallside Windows SC-V Casement at rank #564 of 1,352 Window entries with U 0.19 to 0.26 across 56 configurations. Solar heat gain ranges between 0.16 and 0.42 across Northern, North-Central, South-Central, Southern.
Is SC-V Casement approved for Northern Zone heating climates?
Prescriptive Northern compliance covers 40 SC-V Casement packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.26, specify the cold-climate glass code explicitly.
What conductive BTU/hr difference separates SC-V Casement from the 0.22 Northern rule?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), SC-V Casement at U 0.19 conducts 114.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What are the practical limitations of specifying SC-V Casement?
Cold-climate owners needing prescriptive U <= 0.22 should pass on SC-V Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install Wallside Windows SC-V Casement in Southern or South-Central zones?
Yes. 38 Southern-certified options inside Wallside Windows SC-V Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.42 SHGC on west-facing glass to avoid excess afternoon solar gain.
What glazing share inside SC-V Casement qualifies as Most Efficient?
No. Exactly 18 of 56 configurations (32.1%) earn ENERGY STAR Most Efficient status in SC-V Casement; the remaining standard v7.0 options pass base zone limits only.
Can homeowners claim Form 5695 credits on Wallside Windows SC-V Casement in 2026?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Wallside Windows upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do building inspectors verify SC-V Casement glass specs on job sites?
Confirm both the paper NFRC label and permanent corner glass etch match line WAW-K-22 and NFRC ID WAW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Wallside Windows SC-V Casement come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)