Skip to main content
Window · Vinyl Frame NFRC VCI · Product Line VCI-K-17 ENERGY STAR Most Efficient Eligible

Vinyl Kraft, Inc. — 2000/2500 Single Hung · Single Hung

Vinyl Kraft, Inc. engineered the 2000/2500 Single Hung Single Hung line for Northern, North-Central, South-Central, Southern, certifying 68 glass-spacer combinations from 0.19 to 0.29 U-Factor and 0.17 to 0.49 SHGC. Relative to other Vinyl models tracked under NFRC VCI, its minimum U-Factor is matches the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.19
SHGC Range
0.17-0.49
Certified Options
68
Category Standing
#564 of 1,352

How does Vinyl Kraft, Inc. 2000/2500 Single Hung compare thermally against Window peers?

Vinyl Kraft, Inc. 2000/2500 Single Hung achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 2000/2500 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 2000/2500 Single Hung (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

2000/2500 Single Hung Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 8 certified Vinyl Kraft, Inc. series, this Single Hung offers a 0.10 U-Factor adjustment span between 0.29 entry options and 0.19 top-performing glazing. Category standing is #564/1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 11 configurations meet ENERGY STAR Most Efficient criteria while 21 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-10-03 and cert timestamp 2025-04-23.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 68 certified glazing combinations for 2000/2500 Single Hung (NFRC VCI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 21 packages (4 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 48 packages (8 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 34 packages (6 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 42 packages (9 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Soft-Lite, LLC — Elements DH20 Double Hung Vinyl 0.19 0.16 68
Soft-Lite, LLC — Imperial Elite DH12E Vinyl 0.19 0.16 68
Northeast Building Products Corporation — Elite DH PW Vinyl 0.19 0.17 76
Northeast Building Products Corporation — Elite NC PW Vinyl 0.19 0.16 77
Wallside Windows — SC-V Casement Vinyl 0.19 0.16 56

What other certified series does Vinyl Kraft, Inc. produce?

Compare other active Vinyl Kraft, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vinyl Kraft, Inc. 2000/2500 Single Hung appear below.

What U-Factor and SHGC range does Vinyl Kraft, Inc. 2000/2500 Single Hung achieve?

Vinyl Kraft, Inc. 2000/2500 Single Hung spans 68 certified configurations with U-Factors between 0.19 and 0.29 and SHGC values from 0.17 to 0.49. Ranked #564 of 1,352 Window families, it carries 11 Most Efficient options.

How does Vinyl Kraft, Inc. 2000/2500 Single Hung satisfy Version 7.0 Northern criteria?

Yes, 21 packages satisfy Northern ENERGY STAR Version 7.0 rules in 2000/2500 Single Hung. Pairing multi-pane insulation down to 0.19 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How does a 3x5 ft 2000/2500 Single Hung window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Vinyl Kraft, Inc. 2000/2500 Single Hung and compare alternatives?

Skip 2000/2500 Single Hung if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 2000/2500 Single Hung options exceeding U 0.22.

How many 2000/2500 Single Hung glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 42 Southern-approved options within 2000/2500 Single Hung spanning SHGC down to 0.17. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside 2000/2500 Single Hung qualifies as Most Efficient?

Within 2000/2500 Single Hung, 16.2% (11 of 68) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

What federal compliance checks govern 2026 2000/2500 Single Hung window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on 2000/2500 Single Hung?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code VCI and product line VCI-K-17, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vinyl Kraft, Inc. 2000/2500 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros