Northeast Building Products Corporation — Elite DH PW · Picture Window
Positioning #564/1,352 in certified Window, Northeast Building Products Corporation Elite DH PW pairs Vinyl frame construction with 76 glazing options rated between 0.17 and 0.31 SHGC across Northern, North-Central, South-Central, Southern. Across 11 certified Northeast Building Products Corporation product families, its thermal resistance spans 0.19 to 0.27 U-Factor and the line includes 22 ENERGY STAR Most Efficient packages (28.9% of line).
- Min U-Factor
- 0.19
- SHGC Range
- 0.17-0.31
- Certified Options
- 76
- Category Standing
- #564 of 1,352
How does Northeast Building Products Corporation Elite DH PW compare thermally against Window peers?
Northeast Building Products Corporation Elite DH PW achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Northeast Building Products Corporation Elite DH PW at rank #564 of 1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.17-0.31 band.
Mapping NFRC SHGC values (0.17 to 0.31) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 22 configurations meet ENERGY STAR Most Efficient criteria while 41 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-03-12. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.19 conducts 114.0 BTU/hr (-18.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 76 certified glazing combinations for Elite DH PW (NFRC NBP) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 41 packages (4 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 68 packages (4 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 42 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 42 packages (18 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Soft-Lite, LLC — Elements DH20 Double Hung | Vinyl | 0.19 | 0.16 | 68 |
| Soft-Lite, LLC — Imperial Elite DH12E | Vinyl | 0.19 | 0.16 | 68 |
| Vinyl Kraft, Inc. — 2000/2500 Single Hung | Vinyl | 0.19 | 0.17 | 68 |
| Energex Window Alliance — Energex Slider | Vinyl | 0.19 | 0.13 | 91 |
| Wallside Windows — SC-V Casement | Vinyl | 0.19 | 0.16 | 56 |
What other certified series does Northeast Building Products Corporation produce?
Compare other active Northeast Building Products Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Camelot/Crusader Elite Casement Picture Window (Sash Insert)
U-Factor 0.19–0.30 · 156 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Northeast Building Products Corporation Elite DH PW appear below.
Where does Northeast Building Products Corporation Elite DH PW stand thermally among ENERGY STAR Window lines?
Testing puts Northeast Building Products Corporation Elite DH PW at rank #564 of 1,352 Window entries with U 0.19 to 0.27 across 76 configurations. Solar heat gain ranges between 0.17 and 0.31 across Northern, North-Central, South-Central, Southern.
Is Elite DH PW approved for Northern Zone heating climates?
Prescriptive Northern compliance covers 41 Elite DH PW packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.27, specify the cold-climate glass code explicitly.
How much winter heat loss does Elite DH PW conduct across a 15 sq ft opening?
Using NFRC NBP U-Factor 0.19, a 15 sq ft Fixed Window (FIXD) assembly conducts 114.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-18.0 BTU/hr margin).
Which situations make Elite DH PW the wrong window or door choice?
Skip Elite DH PW if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Elite DH PW options exceeding U 0.22.
Can you install Northeast Building Products Corporation Elite DH PW in Southern or South-Central zones?
Yes. 42 Southern-certified options inside Northeast Building Products Corporation Elite DH PW satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.31 SHGC on west-facing glass to avoid excess afternoon solar gain.
Are all 76 Elite DH PW configurations ENERGY STAR Most Efficient?
Not every package qualifies: 22 of 76 Elite DH PW glazing builds earn Most Efficient recognition (28.9%), while other variants sit on the standard Version 7.0 tier.
Do 2026 Elite DH PW installations qualify for IRS Section 25C tax credits?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Elite DH PW retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do you cross-check NFRC NBP and product line NBP-K-49 on delivery?
Verify NFRC ID NBP and series NBP-K-49 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Northeast Building Products Corporation Elite DH PW come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)