Skip to main content
Window · Vinyl Frame NFRC NBP · Product Line NBP-K-41 ENERGY STAR Most Efficient Eligible

Northeast Building Products Corporation — Elite Casement · Casement Windows

Positioning #564/1,352 in certified Window, Northeast Building Products Corporation Elite Casement pairs Vinyl frame construction with 173 glazing options rated between 0.15 and 0.27 SHGC across Northern, North-Central, South-Central, Southern. Across 11 certified Northeast Building Products Corporation product families, its thermal resistance spans 0.19 to 0.28 U-Factor and the line includes 34 ENERGY STAR Most Efficient packages (19.7% of line).

Min U-Factor
0.19
SHGC Range
0.15-0.27
Certified Options
173
Category Standing
#564 of 1,352

How does Northeast Building Products Corporation Elite Casement compare thermally against Window peers?

Northeast Building Products Corporation Elite Casement achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Elite CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Elite Casement (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Elite Casement Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 11 certified Northeast Building Products Corporation series, this Casement Windows offers a 0.09 U-Factor adjustment span between 0.28 entry options and 0.19 top-performing glazing. Category standing is #564/1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 34 configurations meet ENERGY STAR Most Efficient criteria while 29 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.19 U-Factor yields 114.0 BTU/hr transfer (-18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2025-03-12 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 173 certified glazing combinations for Elite Casement (NFRC NBP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 29 packages (4 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 130 packages (4 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 160 packages (4 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 160 packages (34 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Northeast Building Products Corporation produce?

Compare other active Northeast Building Products Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Northeast Building Products Corporation Elite Casement appear below.

How efficient is Northeast Building Products Corporation Elite Casement compared with peer Window models?

EPA ENERGY STAR v7.0 records 173 configurations for Northeast Building Products Corporation Elite Casement covering Northern, North-Central, South-Central, Southern, dropping down to U 0.19 versus a 0.20 Window median. Only 34 options earn Most Efficient status.

Which glazing options in Northeast Building Products Corporation Elite Casement meet Northern climate limits?

Northeast Building Products Corporation Elite Casement supplies 29 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for Northeast Building Products Corporation Elite Casement?

Using NFRC NBP U-Factor 0.19, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 114.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-18.0 BTU/hr margin).

What are the practical limitations of specifying Elite Casement?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Elite Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many Elite Casement glazing packages pass Southern solar-heat rules?

Exactly 160 Elite Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.27 glass.

Does Elite Casement carry EPA Most Efficient certification across its lineup?

Only 34 options out of 173 (19.7%) meet tighter Most Efficient U-Factor and SHGC thresholds in Northeast Building Products Corporation Elite Casement, usually requiring triple-pane or upgraded Low-E coatings.

How do the 25C sunset and pre-1978 Lead RRP rules affect Elite Casement?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Northeast Building Products Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

Where are NFRC and IGCC identification marks located on Elite Casement?

Verify NFRC ID NBP and series NBP-K-41 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Northeast Building Products Corporation Elite Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros