Skip to main content
Window · Vinyl Frame NFRC NBP · Product Line NBP-K-54 ENERGY STAR Most Efficient Eligible

Northeast Building Products Corporation — Elite DH · Double Hung

Northeast Building Products Corporation Elite DH is a Double Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.20 across 146 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #671 of 1,352 in Window, its thermal floor is matches the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.16 to 0.28.

Min U-Factor
0.20
SHGC Range
0.16-0.28
Certified Options
146
Category Standing
#671 of 1,352

How does Northeast Building Products Corporation Elite DH compare thermally against Window peers?

Northeast Building Products Corporation Elite DH achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Elite DHHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Elite DH (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Elite DH Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 11 certified Northeast Building Products Corporation series, this Double Hung offers a 0.10 U-Factor adjustment span between 0.30 entry options and 0.20 top-performing glazing. Category standing is #671/1,352 (tied with 70 others at 0.20, more insulating than 45.2% of Window lines).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 12 configurations meet ENERGY STAR Most Efficient criteria while 12 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-03-13. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.20 conducts 120.0 BTU/hr (-12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 146 certified glazing combinations for Elite DH (NFRC NBP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 12 packages (1 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 103 packages (2 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 115 packages (2 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 122 packages (12 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Northeast Building Products Corporation produce?

Compare other active Northeast Building Products Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Northeast Building Products Corporation Elite DH appear below.

How well does Elite DH by Northeast Building Products Corporation insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 146 configurations for Northeast Building Products Corporation Elite DH covering Northern, North-Central, South-Central, Southern, dropping down to U 0.20 versus a 0.20 Window median. Only 12 options earn Most Efficient status.

Is Elite DH approved for Northern Zone heating climates?

Northeast Building Products Corporation Elite DH supplies 12 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.30, so inspect the NFRC order sheet before purchase.

How much winter heat loss does Elite DH conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 120.0 BTU/hr on Elite DH's lowest-U package (0.20), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.30 transfer proportionally more energy.

When should a buyer skip Northeast Building Products Corporation Elite DH and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Elite DH options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in Elite DH?

Yes, Elite DH holds 122 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.

What glazing share inside Elite DH qualifies as Most Efficient?

No. Exactly 12 of 146 configurations (8.2%) earn ENERGY STAR Most Efficient status in Elite DH; the remaining standard v7.0 options pass base zone limits only.

Do 2026 Elite DH installations qualify for IRS Section 25C tax credits?

Any Elite DH purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC NBP and product line NBP-K-54 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code NBP and product line NBP-K-54, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Northeast Building Products Corporation Elite DH come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros