Window · Vinyl Frame NFRC MEI · Product Line MEI-A-255 ENERGY STAR Most Efficient Eligible

MI Windows and Doors, LLC — Restorations V5500/V-1995 Hopper · Awning (Projected)

MI Windows and Doors, LLC engineered the Restorations V5500/V-1995 Hopper Awning, Projected line for Northern, North-Central, South-Central, Southern, certifying 114 glass-spacer combinations from 0.20 to 0.28 U-Factor and 0.13 to 0.44 SHGC. Relative to other Vinyl models tracked under NFRC MEI, its minimum U-Factor is 0.01 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.20
SHGC Range
0.13-0.44
Certified Options
114
Category Standing
#671 of 1,352

How does MI Windows and Doors, LLC Restorations V5500/V-1995 Hopper compare thermally against Window peers?

MI Windows and Doors, LLC Restorations V5500/V-1995 Hopper achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Restorations V5500/V-1995 HopperHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Restorations V5500/V-1995 Hopper (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Restorations V5500/V-1995 Hopper Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places MI Windows and Doors, LLC Restorations V5500/V-1995 Hopper at rank #671 of 1,352 (tied with 70 others at 0.20, more insulating than 45.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.13-0.44 band.

Climate coverage for MI Windows and Doors, LLC Restorations V5500/V-1995 Hopper spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 28 configurations meet ENERGY STAR Most Efficient criteria while 30 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.20 U-Factor yields 120.0 BTU/hr transfer (-12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-11 licensing and 2024-02-29 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 114 certified glazing combinations for Restorations V5500/V-1995 Hopper (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 30 packages (0 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 92 packages (2 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 90 packages (2 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 90 packages (28 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does MI Windows and Doors, LLC produce?

Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC Restorations V5500/V-1995 Hopper appear below.

What U-Factor and SHGC range does MI Windows and Doors, LLC Restorations V5500/V-1995 Hopper achieve?

Built with Vinyl framing in Projected Awning (PRAW) style, MI Windows and Doors, LLC Restorations V5500/V-1995 Hopper offers 114 Version 7.0 configurations from U 0.20 up to 0.28, posting At median against the Window median of 0.20 with 28 Most Efficient picks.

Can homeowners install Restorations V5500/V-1995 Hopper in cold Northern ENERGY STAR counties?

Yes. 30 packages in MI Windows and Doors, LLC Restorations V5500/V-1995 Hopper clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

How much winter heat loss does Restorations V5500/V-1995 Hopper conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Restorations V5500/V-1995 Hopper at U 0.20 conducts 120.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose MI Windows and Doors, LLC Restorations V5500/V-1995 Hopper for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Restorations V5500/V-1995 Hopper options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does Restorations V5500/V-1995 Hopper meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, Restorations V5500/V-1995 Hopper holds 90 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

Are all 114 Restorations V5500/V-1995 Hopper configurations ENERGY STAR Most Efficient?

Not every package qualifies: 28 of 114 Restorations V5500/V-1995 Hopper glazing builds earn Most Efficient recognition (24.6%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 Restorations V5500/V-1995 Hopper window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Restorations V5500/V-1995 Hopper retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do building inspectors verify Restorations V5500/V-1995 Hopper glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line MEI-A-255 and NFRC ID MEI before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC Restorations V5500/V-1995 Hopper come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros