Skip to main content
Window · Vinyl Frame NFRC NTW · Product Line NTW-A-25 ENERGY STAR Most Efficient Eligible

NT Window, Inc. — S150-Slimline Picture Window · Picture Window

With a minimum U-Factor of 0.20—At median compared against the 0.20 Window median—NT Window, Inc. S150-Slimline Picture Window spans 116 tested options across Northern, North-Central, South-Central, Southern up to 0.29 U-Factor. Carrying NFRC CPD code NTW, the Vinyl assembly includes 29 ENERGY STAR Most Efficient packages (25.0% of line) and offers SHGC packages between 0.15 and 0.24.

Min U-Factor
0.20
SHGC Range
0.15-0.24
Certified Options
116
Category Standing
#671 of 1,352

How does NT Window, Inc. S150-Slimline Picture Window compare thermally against Window peers?

NT Window, Inc. S150-Slimline Picture Window achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. S150-Slimline Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing S150-Slimline Picture Window (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

S150-Slimline Picture Window Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), S150-Slimline Picture Window reaches 0.20 on its lowest-conductivity package — #513 of 1,009 in Vinyl, tied with 47 others at 0.20, more insulating than 44.5% of Vinyl lines (+0.01 vs Vinyl peers). Pairing NFRC ID NTW across multi-pane fills shifts U-Factor from 0.29 down toward 0.20.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 29 configurations meet ENERGY STAR Most Efficient criteria while 30 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.20 U-Factor yields 120.0 BTU/hr transfer (-12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2025-02-26 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 116 certified glazing combinations for S150-Slimline Picture Window (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 30 packages (0 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 57 packages (2 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 102 packages (2 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 106 packages (29 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does NT Window, Inc. produce?

Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. S150-Slimline Picture Window appear below.

What U-Factor and SHGC range does NT Window, Inc. S150-Slimline Picture Window achieve?

Built with Vinyl framing in Fixed Window (FIXD) style, NT Window, Inc. S150-Slimline Picture Window offers 116 Version 7.0 configurations from U 0.20 up to 0.29, posting At median against the Window median of 0.20 with 29 Most Efficient picks.

Which glazing options in NT Window, Inc. S150-Slimline Picture Window meet Northern climate limits?

Yes, 30 packages satisfy Northern ENERGY STAR Version 7.0 rules in S150-Slimline Picture Window. Pairing multi-pane insulation down to 0.20 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What BTU/hr heat transfer results from S150-Slimline Picture Window's 0.20 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.20 U-Factor yields 120.0 BTU/hr conductive transfer (-9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for NT Window, Inc. S150-Slimline Picture Window?

Do not specify S150-Slimline Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on S150-Slimline Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is S150-Slimline Picture Window suitable for sunbelt cooling-dominated homes?

Yes, S150-Slimline Picture Window holds 106 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.

Are all 116 S150-Slimline Picture Window configurations ENERGY STAR Most Efficient?

EPA lists 29 Most Efficient options (25.0% share) inside NT Window, Inc. S150-Slimline Picture Window, out of 116 total Version 7.0 entries.

Do 2026 S150-Slimline Picture Window installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify S150-Slimline Picture Window after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.20-0.29, SHGC 0.15-0.24) against permit drawings for line NTW-A-25. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. S150-Slimline Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros