Window · Vinyl Frame NFRC VCI · Product Line VCI-K-10 ENERGY STAR Most Efficient Eligible

Vinyl Kraft, Inc. — TrustGard Horizontal Slider · Double Slider

EPA ENERGY STAR Version 7.0 certifies 76 variants inside Vinyl Kraft, Inc. TrustGard Horizontal Slider, combining Vinyl frame construction with U-Factors spanning 0.21 to 0.28 and SHGC 0.17 to 0.49. Qualifying for Northern, North-Central, South-Central, Southern, this Double Slider family places #742 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.21
SHGC Range
0.17-0.49
Certified Options
76
Category Standing
#742 of 1,352

How does Vinyl Kraft, Inc. TrustGard Horizontal Slider compare thermally against Window peers?

Vinyl Kraft, Inc. TrustGard Horizontal Slider achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. TrustGard Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing TrustGard Horizontal Slider (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

TrustGard Horizontal Slider Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), TrustGard Horizontal Slider is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.21-0.28.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 7 configurations meet ENERGY STAR Most Efficient criteria while 29 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-02-20 and FENSTAR license 2018-10-03 inside EPA Version 7.0 tables. Heat transfer computes to 126.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 76 certified glazing combinations for TrustGard Horizontal Slider (NFRC VCI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 29 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 48 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 40 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 40 packages (7 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Wallside Windows — SDH Double Hung Vinyl 0.21 0.18 72
United Window & Door Mfg., Inc. — 9640 Picture Window Vinyl 0.21 0.17 81
Vytex Corporation — Fortis Double Hung Vinyl 0.21 0.16 68
Wallside Windows — ESTDS Double Slider Vinyl 0.21 0.18 64
MGM Industries — 4600 Picture Window / Transom Vinyl 0.21 0.19 57

What other certified series does Vinyl Kraft, Inc. produce?

Compare other active Vinyl Kraft, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vinyl Kraft, Inc. TrustGard Horizontal Slider appear below.

Where does Vinyl Kraft, Inc. TrustGard Horizontal Slider stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 76 configurations for Vinyl Kraft, Inc. TrustGard Horizontal Slider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.21 versus a 0.20 Window median. Only 7 options earn Most Efficient status.

Can homeowners install TrustGard Horizontal Slider in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 29 TrustGard Horizontal Slider packages (U floor 0.21, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates TrustGard Horizontal Slider from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying TrustGard Horizontal Slider?

Skip TrustGard Horizontal Slider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on TrustGard Horizontal Slider options exceeding U 0.22.

Is TrustGard Horizontal Slider suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 40 Southern-approved options within TrustGard Horizontal Slider spanning SHGC down to 0.17. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside TrustGard Horizontal Slider qualifies as Most Efficient?

Only 7 options out of 76 (9.2%) meet tighter Most Efficient U-Factor and SHGC thresholds in Vinyl Kraft, Inc. TrustGard Horizontal Slider, usually requiring triple-pane or upgraded Low-E coatings.

Can homeowners claim Form 5695 credits on Vinyl Kraft, Inc. TrustGard Horizontal Slider in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current TrustGard Horizontal Slider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC VCI and product line VCI-K-10 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code VCI and product line VCI-K-10, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vinyl Kraft, Inc. TrustGard Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros