Window · Vinyl Frame NFRC WAW · Product Line WAW-K-23 ENERGY STAR Most Efficient Eligible

Wallside Windows — AC-V Awning · Awning (Projected)

Positioning #564/1,352 in certified Window, Wallside Windows AC-V Awning pairs Vinyl frame construction with 55 glazing options rated between 0.16 and 0.42 SHGC across Northern, North-Central, South-Central, Southern. Across 7 certified Wallside Windows product families, its thermal resistance spans 0.19 to 0.26 U-Factor and the line includes 17 ENERGY STAR Most Efficient packages (30.9% of line).

Min U-Factor
0.19
SHGC Range
0.16-0.42
Certified Options
55
Category Standing
#564 of 1,352

How does Wallside Windows AC-V Awning compare thermally against Window peers?

Wallside Windows AC-V Awning achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. AC-V AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing AC-V Awning (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

AC-V Awning Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across AC-V Awning spans 55 NFRC test records (WAW), ranking #564 of 1,352 Window families (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%). Its 0.19 thermal floor compares at At median against the Vinyl median (0.19).

Regional qualification covers Northern, North-Central, South-Central, Southern. 17 configurations meet ENERGY STAR Most Efficient criteria while 35 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.19 U-Factor yields 114.0 BTU/hr transfer (-18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-08-23 licensing and 2024-11-15 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 55 certified glazing combinations for AC-V Awning (NFRC WAW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 35 packages (10 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 46 packages (16 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 38 packages (16 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 38 packages (17 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Soft-Lite, LLC — Elements DH20 Double Hung Vinyl 0.19 0.16 68
Soft-Lite, LLC — Imperial Elite DH12E Vinyl 0.19 0.16 68
Vinyl Kraft, Inc. — 2000/2500 Single Hung Vinyl 0.19 0.17 68
Northeast Building Products Corporation — Elite DH PW Vinyl 0.19 0.17 76
Northeast Building Products Corporation — Elite NC PW Vinyl 0.19 0.16 77

What other certified series does Wallside Windows produce?

Compare other active Wallside Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wallside Windows AC-V Awning appear below.

How efficient is Wallside Windows AC-V Awning compared with peer Window models?

Across 55 tested NFRC glazing configurations, Wallside Windows AC-V Awning with Vinyl framing and Projected Awning (PRAW) style reaches a 0.19 minimum U-Factor and 0.16-0.42 SHGC band. It places #564 among 1,352 Window series—top 49.6%.

Is AC-V Awning approved for Northern Zone heating climates?

Yes. 35 packages in Wallside Windows AC-V Awning clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.26.

How does a 3x5 ft AC-V Awning window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), AC-V Awning at U 0.19 conducts 114.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What homeowner profiles are a poor match for Wallside Windows AC-V Awning?

Cold-climate owners needing prescriptive U <= 0.22 should pass on AC-V Awning options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many AC-V Awning glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 38 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Wallside Windows AC-V Awning, while total line SHGC reaches 0.42 in colder packages.

Does AC-V Awning carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 17 of 55 AC-V Awning glazing builds earn Most Efficient recognition (30.9%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 AC-V Awning window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on AC-V Awning?

Match the NFRC thermal sticker for code WAW and line WAW-K-23 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wallside Windows AC-V Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros