Skip to main content
Window · Vinyl Frame NFRC MGM · Product Line MGM-A-5

MGM Industries — 6010/6060 Single Hung · Single Hung

Across 7 MGM Industries certified families, 6010/6060 Single Hung supplies 641 Single Hung configurations starting at 0.23 U-Factor and 0.13 SHGC for North-Central, South-Central, Southern, reaching up to 0.31 U-Factor and 0.29 SHGC. Its thermal floor ranks #936 of 1,352 category entries—0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.23
SHGC Range
0.13-0.29
Certified Options
641
Category Standing
#936 of 1,352

How does MGM Industries 6010/6060 Single Hung compare thermally against Window peers?

MGM Industries 6010/6060 Single Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 6010/6060 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 6010/6060 Single Hung (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

6010/6060 Single Hung Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 6010/6060 Single Hung is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.23-0.31.

Climate coverage for MGM Industries 6010/6060 Single Hung spans North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.23 U-Factor yields 138.0 BTU/hr transfer (+6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-11-08 licensing and 2026-04-29 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 641 certified glazing combinations for 6010/6060 Single Hung (NFRC MGM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 190 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 318 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 564 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does MGM Industries produce?

Compare other active MGM Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MGM Industries 6010/6060 Single Hung appear below.

Where does MGM Industries 6010/6060 Single Hung stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 641 configurations for MGM Industries 6010/6060 Single Hung covering North-Central, South-Central, Southern, dropping down to U 0.23 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does MGM Industries 6010/6060 Single Hung qualify for the ENERGY STAR Northern Zone?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.23). Focus on North-Central, South-Central, Southern glazing applications where SHGC 0.13-0.29 manages cooling loads.

What conductive BTU/hr difference separates 6010/6060 Single Hung from the 0.22 Northern rule?

At U 0.23, a standard 3x5 ft (15 sq ft) 6010/6060 Single Hung opening transfers 138.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +6.0 BTU/hr difference.

What are the practical limitations of specifying 6010/6060 Single Hung?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 6010/6060 Single Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Can you install MGM Industries 6010/6060 Single Hung in Southern or South-Central zones?

Across North-Central, South-Central, Southern, 564 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside MGM Industries 6010/6060 Single Hung, while total line SHGC reaches 0.29 in colder packages.

Does 6010/6060 Single Hung carry EPA Most Efficient certification across its lineup?

Zero glazing builds inside 6010/6060 Single Hung's 641 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Can homeowners claim Form 5695 credits on MGM Industries 6010/6060 Single Hung in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 6010/6060 Single Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC MGM and product line MGM-A-5 on delivery?

Inspectors match the temporary NFRC sticker (U 0.23-0.31, SHGC 0.13-0.29) against permit drawings for line MGM-A-5. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MGM Industries 6010/6060 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros