Skip to main content
Window · Vinyl Frame NFRC SMA · Product Line SMA-A-30

Seaway Manufacturing Corporation — Amerivu Picture Window · Picture Window

With a minimum U-Factor of 0.23—+0.03 compared against the 0.20 Window median—Seaway Manufacturing Corporation Amerivu Picture Window spans 537 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code SMA, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.13 and 0.53.

Min U-Factor
0.23
SHGC Range
0.13-0.53
Certified Options
537
Category Standing
#936 of 1,352

How does Seaway Manufacturing Corporation Amerivu Picture Window compare thermally against Window peers?

Seaway Manufacturing Corporation Amerivu Picture Window achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Amerivu Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Amerivu Picture Window (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Amerivu Picture Window Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Amerivu Picture Window is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.23-0.32.

Mapping NFRC SHGC values (0.13 to 0.53) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 20 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 138.0 BTU/hr (+4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2023-11-21.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 537 certified glazing combinations for Amerivu Picture Window (NFRC SMA) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 20 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 112 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 317 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 465 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Seaway Manufacturing Corporation produce?

Compare other active Seaway Manufacturing Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Seaway Manufacturing Corporation Amerivu Picture Window appear below.

Where does Seaway Manufacturing Corporation Amerivu Picture Window stand thermally among ENERGY STAR Window lines?

Seaway Manufacturing Corporation Amerivu Picture Window spans 537 certified configurations with U-Factors between 0.23 and 0.32 and SHGC values from 0.13 to 0.53. Ranked #936 of 1,352 Window families, it carries 0 Most Efficient options.

How does Seaway Manufacturing Corporation Amerivu Picture Window satisfy Version 7.0 Northern criteria?

Northern qualification on Amerivu Picture Window relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 20 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

How does a 3x5 ft Amerivu Picture Window window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Amerivu Picture Window at U 0.23 conducts 138.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying Amerivu Picture Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Amerivu Picture Window options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many Amerivu Picture Window glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 465 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Seaway Manufacturing Corporation Amerivu Picture Window, while total line SHGC reaches 0.53 in colder packages.

Does Amerivu Picture Window carry EPA Most Efficient certification across its lineup?

All 537 Amerivu Picture Window listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

How do the 25C sunset and pre-1978 Lead RRP rules affect Amerivu Picture Window?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on Amerivu Picture Window?

Inspectors match the temporary NFRC sticker (U 0.23-0.32, SHGC 0.13-0.53) against permit drawings for line SMA-A-30. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Seaway Manufacturing Corporation Amerivu Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros