Skip to main content
Window · Vinyl Frame NFRC SMA · Product Line SMA-A-22 ENERGY STAR Most Efficient Eligible

Seaway Manufacturing Corporation — Lighthouse/Commander/Epiphany Awning · Awning (Projected)

Across 8 Seaway Manufacturing Corporation certified families, Lighthouse/Commander/Epiphany Awning supplies 2,513 Awning, Projected configurations starting at 0.16 U-Factor and 0.09 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.41 SHGC. Its thermal floor ranks #250 of 1,352 category entries—0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.16
SHGC Range
0.09-0.41
Certified Options
2,513
Category Standing
#250 of 1,352

How does Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning compare thermally against Window peers?

Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Lighthouse/Commander/Epiphany AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Lighthouse/Commander/Epiphany Awning (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Lighthouse/Commander/Epiphany Awning Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Lighthouse/Commander/Epiphany Awning spans 2,513 NFRC test records (SMA), ranking #250 of 1,352 Window families (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%). Its 0.16 thermal floor compares at -0.03 against the Vinyl median (0.19).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 862 configurations meet ENERGY STAR Most Efficient criteria while 842 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors SMA to 2024-10-31 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 96.0 BTU/hr conductive loss (-27.3% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,513 certified glazing combinations for Lighthouse/Commander/Epiphany Awning (NFRC SMA) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 842 packages (518 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,273 packages (839 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 2,211 packages (753 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,211 packages (776 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Seaway Manufacturing Corporation produce?

Compare other active Seaway Manufacturing Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning appear below.

What thermal performance numbers separate Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning from peers?

Testing puts Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning at rank #250 of 1,352 Window entries with U 0.16 to 0.28 across 2,513 configurations. Solar heat gain ranges between 0.09 and 0.41 across Northern, North-Central, South-Central, Southern.

Does Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 842 Lighthouse/Commander/Epiphany Awning packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

How much winter heat loss does Lighthouse/Commander/Epiphany Awning conduct across a 15 sq ft opening?

Using NFRC SMA U-Factor 0.16, a 15 sq ft Projected Awning (PRAW) assembly conducts 96.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-36.0 BTU/hr margin).

When should a buyer skip Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Lighthouse/Commander/Epiphany Awning options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is Lighthouse/Commander/Epiphany Awning suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 2,211 Southern-approved options within Lighthouse/Commander/Epiphany Awning spanning SHGC down to 0.09. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 2,513 Lighthouse/Commander/Epiphany Awning configurations ENERGY STAR Most Efficient?

Not every package qualifies: 862 of 2,513 Lighthouse/Commander/Epiphany Awning glazing builds earn Most Efficient recognition (34.3%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 Lighthouse/Commander/Epiphany Awning window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Seaway Manufacturing Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify Lighthouse/Commander/Epiphany Awning glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.16-0.28, SHGC 0.09-0.41) against permit drawings for line SMA-A-22. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Seaway Manufacturing Corporation Lighthouse/Commander/Epiphany Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros