Skip to main content
Window · Vinyl Frame NFRC PWS · Product Line PWS-A-7 ENERGY STAR Most Efficient Eligible

Paradigm Window Solutions — 8352 Awning · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 2,446 variants inside Paradigm Window Solutions 8352 Awning, combining Vinyl frame construction with U-Factors spanning 0.16 to 0.32 and SHGC 0.12 to 0.43. Qualifying for Northern, North-Central, South-Central, Southern, this Awning, Projected family places #250 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.16
SHGC Range
0.12-0.43
Certified Options
2,446
Category Standing
#250 of 1,352

How does Paradigm Window Solutions 8352 Awning compare thermally against Window peers?

Paradigm Window Solutions 8352 Awning achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 8352 AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 8352 Awning (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

8352 Awning Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Paradigm Window Solutions 8352 Awning at rank #250 of 1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.12-0.43 band.

Regional qualification covers Northern, North-Central, South-Central, Southern. 190 configurations meet ENERGY STAR Most Efficient criteria while 301 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-05-21 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,446 certified glazing combinations for 8352 Awning (NFRC PWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 301 packages (50 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 862 packages (106 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,234 packages (93 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,021 packages (177 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Paradigm Window Solutions produce?

Compare other active Paradigm Window Solutions certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Paradigm Window Solutions 8352 Awning appear below.

What U-Factor and SHGC range does Paradigm Window Solutions 8352 Awning achieve?

Across 2,446 tested NFRC glazing configurations, Paradigm Window Solutions 8352 Awning with Vinyl framing and Projected Awning (PRAW) style reaches a 0.16 minimum U-Factor and 0.12-0.43 SHGC band. It places #250 among 1,352 Window series—top 26.7%.

How does Paradigm Window Solutions 8352 Awning satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 301 8352 Awning packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

How does a 3x5 ft 8352 Awning window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 8352 Awning at U 0.16 conducts 96.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Paradigm Window Solutions 8352 Awning and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 8352 Awning options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in 8352 Awning?

Yes. 2,021 Southern-certified options inside Paradigm Window Solutions 8352 Awning satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.43 SHGC on west-facing glass to avoid excess afternoon solar gain.

How many Paradigm Window Solutions 8352 Awning variants earn ENERGY STAR Most Efficient?

Not every package qualifies: 190 of 2,446 8352 Awning glazing builds earn Most Efficient recognition (7.8%), while other variants sit on the standard Version 7.0 tier.

Can homeowners claim Form 5695 credits on Paradigm Window Solutions 8352 Awning in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 8352 Awning installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify 8352 Awning after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.16-0.32, SHGC 0.12-0.43) against permit drawings for line PWS-A-7. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Paradigm Window Solutions 8352 Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros