Skip to main content
Window · Vinyl Frame NFRC SIL · Product Line SIL-N-2

Silver Line Building Products — 1200 Double Hung · Double Hung

With a minimum U-Factor of 0.25—+0.05 compared against the 0.20 Window median—Silver Line Building Products 1200 Double Hung spans 283 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code SIL, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.18 and 0.51.

Min U-Factor
0.25
SHGC Range
0.18-0.51
Certified Options
283
Category Standing
#1,174 of 1,352

How does Silver Line Building Products 1200 Double Hung compare thermally against Window peers?

Silver Line Building Products 1200 Double Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1200 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 1200 Double Hung (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1200 Double Hung Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 1200 Double Hung spans 283 NFRC test records (SIL), ranking #1,174 of 1,352 Window families (tied with 81 others at 0.25, more insulating than 7.2% of Window lines). Its 0.25 thermal floor compares at +0.06 against the Vinyl median (0.19).

Climate coverage for Silver Line Building Products 1200 Double Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 2 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.25 U-Factor yields 150.0 BTU/hr transfer (+18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-10-03 licensing and 2025-08-11 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 283 certified glazing combinations for 1200 Double Hung (NFRC SIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 2 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 9 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 82 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 276 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Silver Line Building Products produce?

Compare other active Silver Line Building Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Silver Line Building Products 1200 Double Hung appear below.

How efficient is Silver Line Building Products 1200 Double Hung compared with peer Window models?

Silver Line Building Products 1200 Double Hung spans 283 certified configurations with U-Factors between 0.25 and 0.32 and SHGC values from 0.18 to 0.51. Ranked #1,174 of 1,352 Window families, it carries 0 Most Efficient options.

Which glazing options in Silver Line Building Products 1200 Double Hung meet Northern climate limits?

While Silver Line Building Products 1200 Double Hung misses the <= 0.22 prescriptive mark (floor U 0.25), 2 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

What conductive BTU/hr difference separates 1200 Double Hung from the 0.22 Northern rule?

At U 0.25, a standard 3x5 ft (15 sq ft) 1200 Double Hung opening transfers 150.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +18.0 BTU/hr difference.

What are the practical limitations of specifying 1200 Double Hung?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1200 Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install Silver Line Building Products 1200 Double Hung in Southern or South-Central zones?

Yes, 1200 Double Hung holds 276 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.18 SHGC in cooling climates.

What glazing share inside 1200 Double Hung qualifies as Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 283 1200 Double Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What federal compliance checks govern 2026 1200 Double Hung window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 1200 Double Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered Silver Line Building Products 1200 Double Hung units match permits?

Match the NFRC thermal sticker for code SIL and line SIL-N-2 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Silver Line Building Products 1200 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros