Window · Vinyl Frame NFRC SIL · Product Line SIL-N-66 ENERGY STAR Most Efficient Eligible

Silver Line Building Products — Series 5840/1580TR Transom · Transom

EPA ENERGY STAR Version 7.0 certifies 1,741 variants inside Silver Line Building Products Series 5840/1580TR Transom, combining Vinyl frame construction with U-Factors spanning 0.19 to 0.32 and SHGC 0.14 to 0.52. Qualifying for Northern, North-Central, South-Central, Southern, this Transom family places #564 of 1,352 among 1,352 Window families and posts matches the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.19
SHGC Range
0.14-0.52
Certified Options
1,741
Category Standing
#564 of 1,352

How does Silver Line Building Products Series 5840/1580TR Transom compare thermally against Window peers?

Silver Line Building Products Series 5840/1580TR Transom achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Series 5840/1580TR TransomHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Series 5840/1580TR Transom (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Series 5840/1580TR Transom Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Silver Line Building Products Series 5840/1580TR Transom standing at #564 of 1,352 certified Window product series, tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%. Comparing Vinyl profiles alone (median 0.19) shows At median before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 40 configurations meet ENERGY STAR Most Efficient criteria while 219 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.19 U-Factor yields 114.0 BTU/hr transfer (-18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-10-03 licensing and 2025-04-23 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,741 certified glazing combinations for Series 5840/1580TR Transom (NFRC SIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 219 packages (7 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 720 packages (14 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 930 packages (10 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,244 packages (36 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Silver Line Building Products produce?

Compare other active Silver Line Building Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Silver Line Building Products Series 5840/1580TR Transom appear below.

How well does Series 5840/1580TR Transom by Silver Line Building Products insulate relative to Window benchmarks?

Testing puts Silver Line Building Products Series 5840/1580TR Transom at rank #564 of 1,352 Window entries with U 0.19 to 0.32 across 1,741 configurations. Solar heat gain ranges between 0.14 and 0.52 across Northern, North-Central, South-Central, Southern.

Does Silver Line Building Products Series 5840/1580TR Transom qualify for the ENERGY STAR Northern Zone?

Yes. 219 packages in Silver Line Building Products Series 5840/1580TR Transom clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How do you calculate winter heat conduction for Silver Line Building Products Series 5840/1580TR Transom?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Series 5840/1580TR Transom at U 0.19 conducts 114.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying Series 5840/1580TR Transom?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Series 5840/1580TR Transom options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

How many Series 5840/1580TR Transom glazing packages pass Southern solar-heat rules?

Yes. 1,244 Southern-certified options inside Silver Line Building Products Series 5840/1580TR Transom satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.52 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 1,741 Series 5840/1580TR Transom configurations ENERGY STAR Most Efficient?

Within Series 5840/1580TR Transom, 2.3% (40 of 1,741) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect Series 5840/1580TR Transom?

Any Series 5840/1580TR Transom purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on Series 5840/1580TR Transom?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code SIL and product line SIL-N-66, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Silver Line Building Products Series 5840/1580TR Transom come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros