Skip to main content
Window · Vinyl Frame NFRC LWW · Product Line LWW-K-17 ENERGY STAR Most Efficient Eligible

Lindsay Windows — Pinnacle / Healthy Double Slider · Double Slider

EPA ENERGY STAR Version 7.0 certifies 670 variants inside Lindsay Windows Pinnacle / Healthy Double Slider, combining Vinyl frame construction with U-Factors spanning 0.19 to 0.30 and SHGC 0.15 to 0.44. Qualifying for Northern, North-Central, South-Central, Southern, this Double Slider family places #564 of 1,352 among 1,352 Window families and posts matches the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.19
SHGC Range
0.15-0.44
Certified Options
670
Category Standing
#564 of 1,352

How does Lindsay Windows Pinnacle / Healthy Double Slider compare thermally against Window peers?

Lindsay Windows Pinnacle / Healthy Double Slider achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pinnacle / Healthy Double SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Pinnacle / Healthy Double Slider (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pinnacle / Healthy Double Slider Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Lindsay Windows Pinnacle / Healthy Double Slider at rank #564 of 1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.15-0.44 band.

Regional qualification covers Northern, North-Central, South-Central, Southern. 155 configurations meet ENERGY STAR Most Efficient criteria while 246 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors LWW to 2024-02-22 certification (FENSTAR issued 2022-10-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 114.0 BTU/hr conductive loss (-13.6% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 670 certified glazing combinations for Pinnacle / Healthy Double Slider (NFRC LWW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 246 packages (50 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 482 packages (76 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 412 packages (46 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 448 packages (119 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Lindsay Windows produce?

Compare other active Lindsay Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lindsay Windows Pinnacle / Healthy Double Slider appear below.

What thermal performance numbers separate Lindsay Windows Pinnacle / Healthy Double Slider from peers?

Built with Vinyl framing in Dual-Slide Horizontal (HSXX) style, Lindsay Windows Pinnacle / Healthy Double Slider offers 670 Version 7.0 configurations from U 0.19 up to 0.30, posting -0.01 against the Window median of 0.20 with 155 Most Efficient picks.

Does Lindsay Windows Pinnacle / Healthy Double Slider qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 246 Pinnacle / Healthy Double Slider packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.30, specify the cold-climate glass code explicitly.

How much winter heat loss does Pinnacle / Healthy Double Slider conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Lindsay Windows Pinnacle / Healthy Double Slider and compare alternatives?

Skip Pinnacle / Healthy Double Slider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle / Healthy Double Slider options exceeding U 0.22.

Does Pinnacle / Healthy Double Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 448 Southern-approved options within Pinnacle / Healthy Double Slider spanning SHGC down to 0.15. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in Pinnacle / Healthy Double Slider holds Most Efficient recognition?

Not every package qualifies: 155 of 670 Pinnacle / Healthy Double Slider glazing builds earn Most Efficient recognition (23.1%), while other variants sit on the standard Version 7.0 tier.

Can homeowners claim Form 5695 credits on Lindsay Windows Pinnacle / Healthy Double Slider in 2026?

Any Pinnacle / Healthy Double Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Lindsay Windows Pinnacle / Healthy Double Slider units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code LWW and product line LWW-K-17, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lindsay Windows Pinnacle / Healthy Double Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)