Skip to main content
Window · Vinyl Frame NFRC HII · Product Line HII-M-47 ENERGY STAR Most Efficient Eligible

Harvey Industries, Inc. — Welded Vinyl Rolling Window · Double Slider

Harvey Industries, Inc. Welded Vinyl Rolling Window is a Double Slider assembly with a Vinyl frame that reaches a minimum U-Factor of 0.19 across 653 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #564 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.16 to 0.50.

Min U-Factor
0.19
SHGC Range
0.16-0.50
Certified Options
653
Category Standing
#564 of 1,352

How does Harvey Industries, Inc. Welded Vinyl Rolling Window compare thermally against Window peers?

Harvey Industries, Inc. Welded Vinyl Rolling Window achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Welded Vinyl Rolling WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Welded Vinyl Rolling Window (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Welded Vinyl Rolling Window Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Harvey Industries, Inc. Welded Vinyl Rolling Window at rank #564 of 1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.16-0.50 band.

Mapping NFRC SHGC values (0.16 to 0.50) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 56 configurations meet ENERGY STAR Most Efficient criteria while 196 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-10-03 and v7.0 data certification on 2024-02-27. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.19 conducts 114.0 BTU/hr (-18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 653 certified glazing combinations for Welded Vinyl Rolling Window (NFRC HII) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 196 packages (29 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 249 packages (39 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 296 packages (21 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 424 packages (31 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Harvey Industries, Inc. produce?

Compare other active Harvey Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Harvey Industries, Inc. Welded Vinyl Rolling Window appear below.

What U-Factor and SHGC range does Harvey Industries, Inc. Welded Vinyl Rolling Window achieve?

EPA ENERGY STAR v7.0 records 653 configurations for Harvey Industries, Inc. Welded Vinyl Rolling Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.19 versus a 0.20 Window median. Only 56 options earn Most Efficient status.

Which glazing options in Harvey Industries, Inc. Welded Vinyl Rolling Window meet Northern climate limits?

Harvey Industries, Inc. Welded Vinyl Rolling Window supplies 196 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for Harvey Industries, Inc. Welded Vinyl Rolling Window?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Welded Vinyl Rolling Window at U 0.19 conducts 114.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Harvey Industries, Inc. Welded Vinyl Rolling Window for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Welded Vinyl Rolling Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Does Welded Vinyl Rolling Window meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 424 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Harvey Industries, Inc. Welded Vinyl Rolling Window, while total line SHGC reaches 0.50 in colder packages.

Does Welded Vinyl Rolling Window carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 56 of 653 Welded Vinyl Rolling Window glazing builds earn Most Efficient recognition (8.6%), while other variants sit on the standard Version 7.0 tier.

What 2026 federal tax credit and Lead RRP rules apply to Welded Vinyl Rolling Window?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Harvey Industries, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC HII and product line HII-M-47 on delivery?

Match the NFRC thermal sticker for code HII and line HII-M-47 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Harvey Industries, Inc. Welded Vinyl Rolling Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros