Window · Vinyl Frame NFRC VWS · Product Line VWS-A-65 ENERGY STAR Most Efficient Eligible

Value Windows & Doors — Onyx/GSCO-SHT-2807 · Single Hung

Value Windows & Doors engineered the Onyx/GSCO-SHT-2807 Single Hung line for Northern, North-Central, South-Central, Southern, certifying 777 glass-spacer combinations from 0.19 to 0.32 U-Factor and 0.08 to 0.22 SHGC. Relative to other Vinyl models tracked under NFRC VWS, its minimum U-Factor is matches the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.19
SHGC Range
0.08-0.22
Certified Options
777
Category Standing
#564 of 1,352

How does Value Windows & Doors Onyx/GSCO-SHT-2807 compare thermally against Window peers?

Value Windows & Doors Onyx/GSCO-SHT-2807 achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Onyx/GSCO-SHT-2807Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Onyx/GSCO-SHT-2807 (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Onyx/GSCO-SHT-2807 Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Onyx/GSCO-SHT-2807 is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.19-0.32.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 145 configurations meet ENERGY STAR Most Efficient criteria while 41 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-31 and cert timestamp 2024-07-30.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 777 certified glazing combinations for Onyx/GSCO-SHT-2807 (NFRC VWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 41 packages (0 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 234 packages (48 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 417 packages (48 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 777 packages (145 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Value Windows & Doors produce?

Compare other active Value Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Value Windows & Doors Onyx/GSCO-SHT-2807 appear below.

How well does Onyx/GSCO-SHT-2807 by Value Windows & Doors insulate relative to Window benchmarks?

Value Windows & Doors Onyx/GSCO-SHT-2807 spans 777 certified configurations with U-Factors between 0.19 and 0.32 and SHGC values from 0.08 to 0.22. Ranked #564 of 1,352 Window families, it carries 145 Most Efficient options.

How does Value Windows & Doors Onyx/GSCO-SHT-2807 satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 41 compliant Northern packages inside Onyx/GSCO-SHT-2807, reaching down to U 0.19. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How does a 3x5 ft Onyx/GSCO-SHT-2807 window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying Onyx/GSCO-SHT-2807?

Skip Onyx/GSCO-SHT-2807 if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Onyx/GSCO-SHT-2807 options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in Onyx/GSCO-SHT-2807?

Warm-climate homeowners have 777 Southern-approved options within Onyx/GSCO-SHT-2807 spanning SHGC down to 0.08. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in Onyx/GSCO-SHT-2807 holds Most Efficient recognition?

No. Exactly 145 of 777 configurations (18.7%) earn ENERGY STAR Most Efficient status in Onyx/GSCO-SHT-2807; the remaining standard v7.0 options pass base zone limits only.

What 2026 federal tax credit and Lead RRP rules apply to Onyx/GSCO-SHT-2807?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Onyx/GSCO-SHT-2807 installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do building inspectors verify Onyx/GSCO-SHT-2807 glass specs on job sites?

Verify NFRC ID VWS and series VWS-A-65 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Value Windows & Doors Onyx/GSCO-SHT-2807 come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)