Skip to main content
Window · Vinyl Frame NFRC SIL · Product Line SIL-N-21

Silver Line Building Products — V1/2292/2392 Horizontal Slider · Single Slider

Positioning #1,034/1,352 in certified Window, Silver Line Building Products V1/2292/2392 Horizontal Slider pairs Vinyl frame construction with 194 glazing options rated between 0.19 and 0.53 SHGC across Northern, North-Central, South-Central, Southern. Across 10 certified Silver Line Building Products product families, its thermal resistance spans 0.24 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.24
SHGC Range
0.19-0.53
Certified Options
194
Category Standing
#1,034 of 1,352

How does Silver Line Building Products V1/2292/2392 Horizontal Slider compare thermally against Window peers?

Silver Line Building Products V1/2292/2392 Horizontal Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. V1/2292/2392 Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing V1/2292/2392 Horizontal Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

V1/2292/2392 Horizontal Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), V1/2292/2392 Horizontal Slider reaches 0.24 on its lowest-conductivity package — #798 of 1,009 in Vinyl, tied with 108 others at 0.24, more insulating than 10.2% of Vinyl lines (+0.05 vs Vinyl peers). Pairing NFRC ID SIL across multi-pane fills shifts U-Factor from 0.32 down toward 0.24.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 10 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-08-11 and FENSTAR license 2018-10-03 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 194 certified glazing combinations for V1/2292/2392 Horizontal Slider (NFRC SIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 10 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 38 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 65 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 168 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Silver Line Building Products produce?

Compare other active Silver Line Building Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Silver Line Building Products V1/2292/2392 Horizontal Slider appear below.

What U-Factor and SHGC range does Silver Line Building Products V1/2292/2392 Horizontal Slider achieve?

EPA ENERGY STAR v7.0 records 194 configurations for Silver Line Building Products V1/2292/2392 Horizontal Slider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Which glazing options in Silver Line Building Products V1/2292/2392 Horizontal Slider meet Northern climate limits?

While Silver Line Building Products V1/2292/2392 Horizontal Slider misses the <= 0.22 prescriptive mark (floor U 0.24), 10 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

What BTU/hr heat transfer results from V1/2292/2392 Horizontal Slider's 0.24 minimum U-Factor?

At U 0.24, a standard 3x5 ft (15 sq ft) V1/2292/2392 Horizontal Slider opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

What are the practical limitations of specifying V1/2292/2392 Horizontal Slider?

Do not specify V1/2292/2392 Horizontal Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on V1/2292/2392 Horizontal Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

What Southern ENERGY STAR v7.0 options exist in V1/2292/2392 Horizontal Slider?

Yes, V1/2292/2392 Horizontal Slider holds 168 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.19 SHGC in cooling climates.

What glazing share inside V1/2292/2392 Horizontal Slider qualifies as Most Efficient?

Zero glazing builds inside V1/2292/2392 Horizontal Slider's 194 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

How do the 25C sunset and pre-1978 Lead RRP rules affect V1/2292/2392 Horizontal Slider?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 V1/2292/2392 Horizontal Slider installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered Silver Line Building Products V1/2292/2392 Horizontal Slider units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code SIL and product line SIL-N-21, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Silver Line Building Products V1/2292/2392 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros