Skip to main content
Window · Vinyl Frame NFRC ELV · Product Line ELV-A-3

Elevate Windows and Doors LLC — Inspire, Inspire Plus, Inspire Star Single Hung · Single Hung

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Single Hung spans 166 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code ELV, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.19 and 0.51.

Min U-Factor
0.24
SHGC Range
0.19-0.51
Certified Options
166
Category Standing
#1,034 of 1,352

How does Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Single Hung compare thermally against Window peers?

Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Single Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Inspire, Inspire Plus, Inspire Star Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Inspire, Inspire Plus, Inspire Star Single Hung (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Inspire, Inspire Plus, Inspire Star Single Hung Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Inspire, Inspire Plus, Inspire Star Single Hung is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 16 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-10-08 licensing and 2024-06-20 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 166 certified glazing combinations for Inspire, Inspire Plus, Inspire Star Single Hung (NFRC ELV) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 16 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 16 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 44 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 150 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Lindsay Windows — 183 Single Slider Vinyl 0.24 0.14 154
Lindsay Windows — 183 Single Hung Vinyl 0.24 0.14 150
Krestmark Industries L. P. — 250 Awning Vinyl 0.24 0.14 190
Silver Line Building Products — V1/2292/2392 Horizontal Slider Vinyl 0.24 0.19 194
Burris Windows — TectView AC Horizontal Slider Vinyl 0.24 0.12 137

What other certified series does Elevate Windows and Doors LLC produce?

Compare other active Elevate Windows and Doors LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Single Hung appear below.

What U-Factor and SHGC range does Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Single Hung achieve?

Testing puts Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Single Hung at rank #1,034 of 1,352 Window entries with U 0.24 to 0.32 across 166 configurations. Solar heat gain ranges between 0.19 and 0.51 across Northern, North-Central, South-Central, Southern.

Is Inspire, Inspire Plus, Inspire Star Single Hung approved for Northern Zone heating climates?

Prescriptive Northern approval ends at U <= 0.22, above Inspire, Inspire Plus, Inspire Star Single Hung's 0.24 minimum. However, 16 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How do you calculate winter heat conduction for Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Single Hung?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Inspire, Inspire Plus, Inspire Star Single Hung at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying Inspire, Inspire Plus, Inspire Star Single Hung?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Inspire, Inspire Plus, Inspire Star Single Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Does Inspire, Inspire Plus, Inspire Star Single Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 150 Inspire, Inspire Plus, Inspire Star Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.19 rather than higher 0.51 glass.

What glazing share inside Inspire, Inspire Plus, Inspire Star Single Hung qualifies as Most Efficient?

All 166 Inspire, Inspire Plus, Inspire Star Single Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

How do the 25C sunset and pre-1978 Lead RRP rules affect Inspire, Inspire Plus, Inspire Star Single Hung?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify Inspire, Inspire Plus, Inspire Star Single Hung after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.24-0.32, SHGC 0.19-0.51) against permit drawings for line ELV-A-3. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros