Skip to main content
Window · Vinyl Frame NFRC ELV · Product Line ELV-A-1

Elevate Windows and Doors LLC — Inspire, Inspire Plus, Inspire Star Slider · Single Slider

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Slider spans 90 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code ELV, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.19 and 0.51.

Min U-Factor
0.24
SHGC Range
0.19-0.51
Certified Options
90
Category Standing
#1,034 of 1,352

How does Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Slider compare thermally against Window peers?

Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Inspire, Inspire Plus, Inspire Star SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Inspire, Inspire Plus, Inspire Star Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Inspire, Inspire Plus, Inspire Star Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Inspire, Inspire Plus, Inspire Star Slider is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.32.

Mapping NFRC SHGC values (0.19 to 0.51) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 12 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors ELV to 2024-06-20 certification (FENSTAR issued 2019-10-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 90 certified glazing combinations for Inspire, Inspire Plus, Inspire Star Slider (NFRC ELV) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 12 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 12 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 30 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 78 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Elevate Windows and Doors LLC produce?

Compare other active Elevate Windows and Doors LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Slider appear below.

Where does Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Slider stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 90 configurations for Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Slider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Can homeowners install Inspire, Inspire Plus, Inspire Star Slider in cold Northern ENERGY STAR counties?

With a 0.24 minimum U-Factor, Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Slider cannot satisfy prescriptive <= 0.22 Northern targets, yet 12 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

How does a 3x5 ft Inspire, Inspire Plus, Inspire Star Slider window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on Inspire, Inspire Plus, Inspire Star Slider's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

When should a buyer skip Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Slider and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Inspire, Inspire Plus, Inspire Star Slider options exceeding U 0.22. Additionally, do not order Horizontal Slider (HSOX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does Inspire, Inspire Plus, Inspire Star Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 78 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Slider, while total line SHGC reaches 0.51 in colder packages.

Are all 90 Inspire, Inspire Plus, Inspire Star Slider configurations ENERGY STAR Most Efficient?

No. Zero of the 90 configurations in Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Slider hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What 2026 federal tax credit and Lead RRP rules apply to Inspire, Inspire Plus, Inspire Star Slider?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Inspire, Inspire Plus, Inspire Star Slider installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC ELV and product line ELV-A-1 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code ELV and product line ELV-A-1, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Elevate Windows and Doors LLC Inspire, Inspire Plus, Inspire Star Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros