Skip to main content
Window · Vinyl Frame NFRC UWD · Product Line UWD-M-60

United Window & Door Mfg., Inc. — 3810-3910 XO Horizontal Slider · Single Slider

United Window & Door Mfg., Inc. 3810-3910 XO Horizontal Slider is a Single Slider assembly with a Vinyl frame that reaches a minimum U-Factor of 0.24 across 116 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,034 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.18 to 0.51.

Min U-Factor
0.24
SHGC Range
0.18-0.51
Certified Options
116
Category Standing
#1,034 of 1,352

How does United Window & Door Mfg., Inc. 3810-3910 XO Horizontal Slider compare thermally against Window peers?

United Window & Door Mfg., Inc. 3810-3910 XO Horizontal Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 3810-3910 XO Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 3810-3910 XO Horizontal Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

3810-3910 XO Horizontal Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 3810-3910 XO Horizontal Slider is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.32.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 8 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors UWD to 2025-03-26 certification (FENSTAR issued 2018-10-03). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 116 certified glazing combinations for 3810-3910 XO Horizontal Slider (NFRC UWD) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 8 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 64 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 26 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 52 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does United Window & Door Mfg., Inc. produce?

Compare other active United Window & Door Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to United Window & Door Mfg., Inc. 3810-3910 XO Horizontal Slider appear below.

How well does 3810-3910 XO Horizontal Slider by United Window & Door Mfg., Inc. insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 116 configurations for United Window & Door Mfg., Inc. 3810-3910 XO Horizontal Slider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Which glazing options in United Window & Door Mfg., Inc. 3810-3910 XO Horizontal Slider meet Northern climate limits?

With a 0.24 minimum U-Factor, United Window & Door Mfg., Inc. 3810-3910 XO Horizontal Slider cannot satisfy prescriptive <= 0.22 Northern targets, yet 8 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

How do you calculate winter heat conduction for United Window & Door Mfg., Inc. 3810-3910 XO Horizontal Slider?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 3810-3910 XO Horizontal Slider at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying 3810-3910 XO Horizontal Slider?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 3810-3910 XO Horizontal Slider options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Is 3810-3910 XO Horizontal Slider suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 52 Southern-approved options within 3810-3910 XO Horizontal Slider spanning SHGC down to 0.18. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in 3810-3910 XO Horizontal Slider holds Most Efficient recognition?

No. Zero of the 116 configurations in United Window & Door Mfg., Inc. 3810-3910 XO Horizontal Slider hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

Can homeowners claim Form 5695 credits on United Window & Door Mfg., Inc. 3810-3910 XO Horizontal Slider in 2026?

Any 3810-3910 XO Horizontal Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered United Window & Door Mfg., Inc. 3810-3910 XO Horizontal Slider units match permits?

Verify NFRC ID UWD and series UWD-M-60 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for United Window & Door Mfg., Inc. 3810-3910 XO Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros