Skip to main content
Window · Vinyl Frame NFRC UWD · Product Line UWD-M-73 ENERGY STAR Most Efficient Eligible

United Window & Door Mfg., Inc. — 9600 Double Hung · Double Hung

United Window & Door Mfg., Inc. engineered the 9600 Double Hung Double Hung line for Northern, North-Central, South-Central, Southern, certifying 168 glass-spacer combinations from 0.21 to 0.32 U-Factor and 0.14 to 0.46 SHGC. Relative to other Vinyl models tracked under NFRC UWD, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.21
SHGC Range
0.14-0.46
Certified Options
168
Category Standing
#742 of 1,352

How does United Window & Door Mfg., Inc. 9600 Double Hung compare thermally against Window peers?

United Window & Door Mfg., Inc. 9600 Double Hung achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 9600 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 9600 Double Hung (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

9600 Double Hung Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 9600 Double Hung spans 168 NFRC test records (UWD), ranking #742 of 1,352 Window families (tied with 88 others at 0.21, more insulating than 38.6% of Window lines). Its 0.21 thermal floor compares at +0.02 against the Vinyl median (0.19).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 10 configurations meet ENERGY STAR Most Efficient criteria while 15 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-10-03 and cert timestamp 2024-02-23.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 168 certified glazing combinations for 9600 Double Hung (NFRC UWD) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 15 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 63 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 102 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 143 packages (10 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Thompson Creek Window Company — 7800 Fixed Vinyl 0.21 0.18 190
Northeast Windows USA, Inc. — PW630 Vinyl 0.21 0.20 133
Northeast Windows USA, Inc. — SL4011 Slider Vinyl 0.21 0.09 212
Thompson Creek Window Company — 7900 Horizontal Slider Vinyl 0.21 0.17 121
Pella Corporation — 250 Series / Power Symphony Double Hung Vinyl 0.21 0.17 217

What other certified series does United Window & Door Mfg., Inc. produce?

Compare other active United Window & Door Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to United Window & Door Mfg., Inc. 9600 Double Hung appear below.

What U-Factor and SHGC range does United Window & Door Mfg., Inc. 9600 Double Hung achieve?

Across 168 tested NFRC glazing configurations, United Window & Door Mfg., Inc. 9600 Double Hung with Vinyl framing and Double-Hung (VSDH) style reaches a 0.21 minimum U-Factor and 0.14-0.46 SHGC band. It places #742 among 1,352 Window series—more insulating than 38.6%.

Does United Window & Door Mfg., Inc. 9600 Double Hung qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 15 compliant Northern packages inside 9600 Double Hung, reaching down to U 0.21. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What conductive BTU/hr difference separates 9600 Double Hung from the 0.22 Northern rule?

Using NFRC UWD U-Factor 0.21, a 15 sq ft Double-Hung (VSDH) assembly conducts 126.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-6.0 BTU/hr margin).

What homeowner profiles are a poor match for United Window & Door Mfg., Inc. 9600 Double Hung?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 9600 Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in 9600 Double Hung?

Yes, 9600 Double Hung holds 143 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.

Does 9600 Double Hung carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 10 of 168 9600 Double Hung glazing builds earn Most Efficient recognition (6.0%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 9600 Double Hung window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 9600 Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on 9600 Double Hung?

Confirm both the paper NFRC label and permanent corner glass etch match line UWD-M-73 and NFRC ID UWD before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for United Window & Door Mfg., Inc. 9600 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros