Skip to main content
Window · Vinyl Frame NFRC UWD · Product Line UWD-M-56 ENERGY STAR Most Efficient Eligible

United Window & Door Mfg., Inc. — 6000 Picture Window · Picture Window

EPA ENERGY STAR Version 7.0 certifies 102 variants inside United Window & Door Mfg., Inc. 6000 Picture Window, combining Vinyl frame construction with U-Factors spanning 0.21 to 0.32 and SHGC 0.16 to 0.49. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #742 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.21
SHGC Range
0.16-0.49
Certified Options
102
Category Standing
#742 of 1,352

How does United Window & Door Mfg., Inc. 6000 Picture Window compare thermally against Window peers?

United Window & Door Mfg., Inc. 6000 Picture Window achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 6000 Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 6000 Picture Window (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

6000 Picture Window Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 6000 Picture Window spans 102 NFRC test records (UWD), ranking #742 of 1,352 Window families (tied with 88 others at 0.21, more insulating than 38.6% of Window lines). Its 0.21 thermal floor compares at +0.02 against the Vinyl median (0.19).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 4 configurations meet ENERGY STAR Most Efficient criteria while 28 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.21 U-Factor yields 126.0 BTU/hr transfer (-6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-10-03 licensing and 2024-10-08 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 102 certified glazing combinations for 6000 Picture Window (NFRC UWD) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 28 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 46 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 37 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 51 packages (4 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Thompson Creek Window Company — 7900 Horizontal Slider Vinyl 0.21 0.17 121
Vinyl Kraft, Inc. — TrustGard Horizontal Slider Vinyl 0.21 0.17 76
Wallside Windows — SDH Double Hung Vinyl 0.21 0.18 72
Northeast Windows USA, Inc. — PW630 Vinyl 0.21 0.20 133
Vytex Corporation — Fortis Double Hung Vinyl 0.21 0.16 68

What other certified series does United Window & Door Mfg., Inc. produce?

Compare other active United Window & Door Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to United Window & Door Mfg., Inc. 6000 Picture Window appear below.

How well does 6000 Picture Window by United Window & Door Mfg., Inc. insulate relative to Window benchmarks?

Testing puts United Window & Door Mfg., Inc. 6000 Picture Window at rank #742 of 1,352 Window entries with U 0.21 to 0.32 across 102 configurations. Solar heat gain ranges between 0.16 and 0.49 across Northern, North-Central, South-Central, Southern.

Can homeowners install 6000 Picture Window in cold Northern ENERGY STAR counties?

Cold-climate buyers get 28 compliant Northern packages inside 6000 Picture Window, reaching down to U 0.21. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What conductive BTU/hr difference separates 6000 Picture Window from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make 6000 Picture Window the wrong window or door choice?

Do not specify 6000 Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 6000 Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is 6000 Picture Window suitable for sunbelt cooling-dominated homes?

Exactly 51 6000 Picture Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.16 rather than higher 0.49 glass.

How many United Window & Door Mfg., Inc. 6000 Picture Window variants earn ENERGY STAR Most Efficient?

Not every package qualifies: 4 of 102 6000 Picture Window glazing builds earn Most Efficient recognition (3.9%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 6000 Picture Window window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC UWD and product line UWD-M-56 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line UWD-M-56 and NFRC ID UWD before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for United Window & Door Mfg., Inc. 6000 Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros