Northeast Windows USA, Inc. — SL4011 Slider · Double Slider
Positioning #742/1,352 in certified Window, Northeast Windows USA, Inc. SL4011 Slider pairs Vinyl frame construction with 212 glazing options rated between 0.09 and 0.48 SHGC across Northern, North-Central, South-Central, Southern. Across 10 certified Northeast Windows USA, Inc. product families, its thermal resistance spans 0.21 to 0.31 U-Factor and the line includes 4 ENERGY STAR Most Efficient packages (1.9% of line).
- Min U-Factor
- 0.21
- SHGC Range
- 0.09-0.48
- Certified Options
- 212
- Category Standing
- #742 of 1,352
How does Northeast Windows USA, Inc. SL4011 Slider compare thermally against Window peers?
Northeast Windows USA, Inc. SL4011 Slider achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Northeast Windows USA, Inc. SL4011 Slider standing at #742 of 1,352 certified Window product series, tied with 88 others at 0.21, more insulating than 38.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.02 before selecting Low-E tiers.
Regional qualification covers Northern, North-Central, South-Central, Southern. 4 configurations meet ENERGY STAR Most Efficient criteria while 46 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2018-10-03 and v7.0 data certification on 2024-03-15. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.21 conducts 126.0 BTU/hr (-6.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 212 certified glazing combinations for SL4011 Slider (NFRC NEW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 46 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 129 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 111 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 122 packages (4 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Pella Corporation — 250 Series / Power Symphony Double Hung | Vinyl | 0.21 | 0.17 | 217 |
| Krestmark Industries L. P. — 250 Fixed Window | Vinyl | 0.21 | 0.16 | 224 |
| Thompson Creek Window Company — 7800 Fixed | Vinyl | 0.21 | 0.18 | 190 |
| WeatherBarr Windows and Doors — 5000 Replacement Casement Picture Window | Vinyl | 0.21 | 0.16 | 244 |
| United Window & Door Mfg., Inc. — 9600 Double Hung | Vinyl | 0.21 | 0.14 | 168 |
What other certified series does Northeast Windows USA, Inc. produce?
Compare other active Northeast Windows USA, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Northeast Windows USA, Inc. SL4011 Slider appear below.
How well does SL4011 Slider by Northeast Windows USA, Inc. insulate relative to Window benchmarks?
Testing puts Northeast Windows USA, Inc. SL4011 Slider at rank #742 of 1,352 Window entries with U 0.21 to 0.31 across 212 configurations. Solar heat gain ranges between 0.09 and 0.48 across Northern, North-Central, South-Central, Southern.
Does Northeast Windows USA, Inc. SL4011 Slider qualify for the ENERGY STAR Northern Zone?
Yes, 46 packages satisfy Northern ENERGY STAR Version 7.0 rules in SL4011 Slider. Pairing multi-pane insulation down to 0.21 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
What conductive BTU/hr difference separates SL4011 Slider from the 0.22 Northern rule?
At U 0.21, a standard 3x5 ft (15 sq ft) SL4011 Slider opening transfers 126.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -6.0 BTU/hr difference.
What homeowner profiles are a poor match for Northeast Windows USA, Inc. SL4011 Slider?
Cold-climate owners needing prescriptive U <= 0.22 should pass on SL4011 Slider options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install Northeast Windows USA, Inc. SL4011 Slider in Southern or South-Central zones?
Warm-climate homeowners have 122 Southern-approved options within SL4011 Slider spanning SHGC down to 0.09. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
What glazing share inside SL4011 Slider qualifies as Most Efficient?
EPA lists 4 Most Efficient options (1.9% share) inside Northeast Windows USA, Inc. SL4011 Slider, out of 212 total Version 7.0 entries.
Do 2026 SL4011 Slider installations qualify for IRS Section 25C tax credits?
Any SL4011 Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
Where are NFRC and IGCC identification marks located on SL4011 Slider?
Inspectors match the temporary NFRC sticker (U 0.21-0.31, SHGC 0.09-0.48) against permit drawings for line NEW-A-19. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Northeast Windows USA, Inc. SL4011 Slider come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)