Skip to main content
Window · Vinyl Frame NFRC HMT · Product Line HMT-A-1

Hometime Windows & Doors — 1600 Single Hung · Single Hung

EPA ENERGY STAR Version 7.0 certifies 124 variants inside Hometime Windows & Doors 1600 Single Hung, combining Vinyl frame construction with U-Factors spanning 0.24 to 0.32 and SHGC 0.13 to 0.23. Qualifying for North-Central, South-Central, Southern, this Single Hung family places #1,034 of 1,352 among 1,352 Window families and posts 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.24
SHGC Range
0.13-0.23
Certified Options
124
Category Standing
#1,034 of 1,352

How does Hometime Windows & Doors 1600 Single Hung compare thermally against Window peers?

Hometime Windows & Doors 1600 Single Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1600 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 1600 Single Hung (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1600 Single Hung Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 1600 Single Hung reaches 0.24 on its lowest-conductivity package — #798 of 1,009 in Vinyl, tied with 108 others at 0.24, more insulating than 10.2% of Vinyl lines (+0.05 vs Vinyl peers). Pairing NFRC ID HMT across multi-pane fills shifts U-Factor from 0.32 down toward 0.24.

Climate coverage for Hometime Windows & Doors 1600 Single Hung spans North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.

Data provenance links certification 2025-07-09 and FENSTAR license 2023-05-09 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 124 certified glazing combinations for 1600 Single Hung (NFRC HMT) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 9 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 20 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 124 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Thompson Creek Window Company — 7800 Double Hung Vinyl 0.24 0.18 132
United Window & Door Mfg., Inc. — 3810-3910 XO Horizontal Slider Vinyl 0.24 0.18 116
Burris Windows — TectView AC Horizontal Slider Vinyl 0.24 0.12 137
Pella Corporation — 150 Series Single Hung Vinyl 0.24 0.20 103
Lindsay Windows — 183 Single Hung Vinyl 0.24 0.14 150

What other certified series does Hometime Windows & Doors produce?

Compare other active Hometime Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Hometime Windows & Doors 1600 Single Hung appear below.

How efficient is Hometime Windows & Doors 1600 Single Hung compared with peer Window models?

EPA ENERGY STAR v7.0 records 124 configurations for Hometime Windows & Doors 1600 Single Hung covering North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Can homeowners install 1600 Single Hung in cold Northern ENERGY STAR counties?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.24). Focus on North-Central, South-Central, Southern glazing applications where SHGC 0.13-0.23 manages cooling loads.

How much winter heat loss does 1600 Single Hung conduct across a 15 sq ft opening?

At U 0.24, a standard 3x5 ft (15 sq ft) 1600 Single Hung opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

Which situations make 1600 Single Hung the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1600 Single Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does 1600 Single Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Across North-Central, South-Central, Southern, 124 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Hometime Windows & Doors 1600 Single Hung, while total line SHGC reaches 0.23 in colder packages.

Does 1600 Single Hung carry EPA Most Efficient certification across its lineup?

ENERGY STAR Most Efficient designation is absent across all 124 1600 Single Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

Can homeowners claim Form 5695 credits on Hometime Windows & Doors 1600 Single Hung in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 1600 Single Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do building inspectors verify 1600 Single Hung glass specs on job sites?

Match the NFRC thermal sticker for code HMT and line HMT-A-1 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Hometime Windows & Doors 1600 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros