Window · Vinyl Frame NFRC HMT · Product Line HMT-A-10 ENERGY STAR Most Efficient Eligible

Hometime Windows & Doors — 314 Casement · Casement Windows

Hometime Windows & Doors 314 Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.22 across 26 certified glazing configurations covering North-Central, South-Central, Southern. Ranked #831 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.17.

Min U-Factor
0.22
SHGC Range
0.12-0.17
Certified Options
26
Category Standing
#831 of 1,352

How does Hometime Windows & Doors 314 Casement compare thermally against Window peers?

Hometime Windows & Doors 314 Casement achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 314 CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 314 Casement (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

314 Casement Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 314 Casement is 0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.22-0.27.

Climate coverage for Hometime Windows & Doors 314 Casement spans North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.

Data provenance links certification 2025-12-03 and FENSTAR license 2023-05-09 inside EPA Version 7.0 tables. Heat transfer computes to 132.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 26 certified glazing combinations for 314 Casement (NFRC HMT) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 8 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 26 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 26 packages (4 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Hometime Windows & Doors produce?

Compare other active Hometime Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Hometime Windows & Doors 314 Casement appear below.

What U-Factor and SHGC range does Hometime Windows & Doors 314 Casement achieve?

Hometime Windows & Doors 314 Casement spans 26 certified configurations with U-Factors between 0.22 and 0.27 and SHGC values from 0.12 to 0.17. Ranked #831 of 1,352 Window families, it carries 4 Most Efficient options.

Which glazing options in Hometime Windows & Doors 314 Casement meet Northern climate limits?

No—with 0 Northern packages and a 0.22 thermal floor, Hometime Windows & Doors 314 Casement targets warmer North-Central, South-Central, Southern climates instead of cold Northern installations.

How much winter heat loss does 314 Casement conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 314 Casement at U 0.22 conducts 132.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What homeowner profiles are a poor match for Hometime Windows & Doors 314 Casement?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 314 Casement options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many 314 Casement glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 26 Southern-approved options within 314 Casement spanning SHGC down to 0.12. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

How many Hometime Windows & Doors 314 Casement variants earn ENERGY STAR Most Efficient?

No. Exactly 4 of 26 configurations (15.4%) earn ENERGY STAR Most Efficient status in 314 Casement; the remaining standard v7.0 options pass base zone limits only.

What federal compliance checks govern 2026 314 Casement window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 314 Casement installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered Hometime Windows & Doors 314 Casement units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line HMT-A-10 and NFRC ID HMT before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Hometime Windows & Doors 314 Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)