Skip to main content
Window · Vinyl Frame NFRC CDW · Product Line CDW-A-31 ENERGY STAR Most Efficient Eligible

California Deluxe Windows Industries, Inc. — S-6300 Tilt & Turn Window · Dual Action (Tilt Turn)

Positioning #831/1,352 in certified Window, California Deluxe Windows Industries, Inc. S-6300 Tilt & Turn Window pairs Vinyl frame construction with 22 glazing options rated between 0.13 and 0.19 SHGC across Northern, North-Central, South-Central, Southern. Across 10 certified California Deluxe Windows Industries, Inc. product families, its thermal resistance spans 0.22 to 0.28 U-Factor and the line includes 6 ENERGY STAR Most Efficient packages (27.3% of line).

Min U-Factor
0.22
SHGC Range
0.13-0.19
Certified Options
22
Category Standing
#831 of 1,352

How does California Deluxe Windows Industries, Inc. S-6300 Tilt & Turn Window compare thermally against Window peers?

California Deluxe Windows Industries, Inc. S-6300 Tilt & Turn Window achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. S-6300 Tilt & Turn WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing S-6300 Tilt & Turn Window (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

S-6300 Tilt & Turn Window Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), S-6300 Tilt & Turn Window reaches 0.22 on its lowest-conductivity package — #640 of 1,009 in Vinyl, tied with 75 others at 0.22, more insulating than 29.1% of Vinyl lines (+0.03 vs Vinyl peers). Pairing NFRC ID CDW across multi-pane fills shifts U-Factor from 0.28 down toward 0.22.

Mapping NFRC SHGC values (0.13 to 0.19) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 6 configurations meet ENERGY STAR Most Efficient criteria while 2 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 132.0 BTU/hr (equal to the 0.22 Northern floor). Records show license timestamp 2023-05-31 and cert timestamp 2026-04-13.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 22 certified glazing combinations for S-6300 Tilt & Turn Window (NFRC CDW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 2 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 20 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 22 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 22 packages (6 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does California Deluxe Windows Industries, Inc. produce?

Compare other active California Deluxe Windows Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to California Deluxe Windows Industries, Inc. S-6300 Tilt & Turn Window appear below.

What U-Factor and SHGC range does California Deluxe Windows Industries, Inc. S-6300 Tilt & Turn Window achieve?

EPA ENERGY STAR v7.0 records 22 configurations for California Deluxe Windows Industries, Inc. S-6300 Tilt & Turn Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.22 versus a 0.20 Window median. Only 6 options earn Most Efficient status.

Can homeowners install S-6300 Tilt & Turn Window in cold Northern ENERGY STAR counties?

Yes, 2 packages satisfy Northern ENERGY STAR Version 7.0 rules in S-6300 Tilt & Turn Window. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What BTU/hr heat transfer results from S-6300 Tilt & Turn Window's 0.22 minimum U-Factor?

At U 0.22, a standard 3x5 ft (15 sq ft) S-6300 Tilt & Turn Window opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.

When should a buyer skip California Deluxe Windows Industries, Inc. S-6300 Tilt & Turn Window and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on S-6300 Tilt & Turn Window options exceeding U 0.22. Additionally, do not order Tilt-Turn Dual Action (DATT) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install California Deluxe Windows Industries, Inc. S-6300 Tilt & Turn Window in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 22 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside California Deluxe Windows Industries, Inc. S-6300 Tilt & Turn Window, while total line SHGC reaches 0.19 in colder packages.

Are all 22 S-6300 Tilt & Turn Window configurations ENERGY STAR Most Efficient?

EPA lists 6 Most Efficient options (27.3% share) inside California Deluxe Windows Industries, Inc. S-6300 Tilt & Turn Window, out of 22 total Version 7.0 entries.

How do the 25C sunset and pre-1978 Lead RRP rules affect S-6300 Tilt & Turn Window?

Any S-6300 Tilt & Turn Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

What permanent glass etch marks verify S-6300 Tilt & Turn Window after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code CDW and product line CDW-A-31, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for California Deluxe Windows Industries, Inc. S-6300 Tilt & Turn Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros