Skip to main content
Window · Vinyl Frame NFRC SII · Product Line SII-A-10

Energy King Windows & Doors Inc. — Pro Series Double Hung · Double Hung

With a minimum U-Factor of 0.22—+0.02 compared against the 0.20 Window median—Energy King Windows & Doors Inc. Pro Series Double Hung spans 12 tested options across Northern, North-Central, South-Central, Southern up to 0.25 U-Factor. Carrying NFRC CPD code SII, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.22 and 0.24.

Min U-Factor
0.22
SHGC Range
0.22-0.24
Certified Options
12
Category Standing
#831 of 1,352

How does Energy King Windows & Doors Inc. Pro Series Double Hung compare thermally against Window peers?

Energy King Windows & Doors Inc. Pro Series Double Hung achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pro Series Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Pro Series Double Hung (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pro Series Double Hung Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Pro Series Double Hung spans 12 NFRC test records (SII), ranking #831 of 1,352 Window families (tied with 104 others at 0.22, more insulating than 30.8% of Window lines). Its 0.22 thermal floor compares at +0.03 against the Vinyl median (0.19).

Climate coverage for Energy King Windows & Doors Inc. Pro Series Double Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 3 combinations qualify in the Northern Zone alongside 8 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2018-08-23 and v7.0 data certification on 2023-08-09. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.22 conducts 132.0 BTU/hr (matching the 0.22 Northern baseline).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 12 certified glazing combinations for Pro Series Double Hung (NFRC SII) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 3 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 12 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 8 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 8 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Energy King Windows & Doors Inc. produce?

Compare other active Energy King Windows & Doors Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Energy King Windows & Doors Inc. Pro Series Double Hung appear below.

What U-Factor and SHGC range does Energy King Windows & Doors Inc. Pro Series Double Hung achieve?

Testing puts Energy King Windows & Doors Inc. Pro Series Double Hung at rank #831 of 1,352 Window entries with U 0.22 to 0.25 across 12 configurations. Solar heat gain ranges between 0.22 and 0.24 across Northern, North-Central, South-Central, Southern.

Is Pro Series Double Hung approved for Northern Zone heating climates?

Energy King Windows & Doors Inc. Pro Series Double Hung supplies 3 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.25, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for Energy King Windows & Doors Inc. Pro Series Double Hung?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.22 U-Factor yields 132.0 BTU/hr conductive transfer (+0.0% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Energy King Windows & Doors Inc. Pro Series Double Hung and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Pro Series Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in Pro Series Double Hung?

Warm-climate homeowners have 8 Southern-approved options within Pro Series Double Hung spanning SHGC down to 0.22. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in Pro Series Double Hung holds Most Efficient recognition?

All 12 Pro Series Double Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Can homeowners claim Form 5695 credits on Energy King Windows & Doors Inc. Pro Series Double Hung in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify Pro Series Double Hung glass specs on job sites?

Match the NFRC thermal sticker for code SII and line SII-A-10 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Energy King Windows & Doors Inc. Pro Series Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)