Skip to main content
Window · Vinyl Frame NFRC TWS · Product Line TWS-K-12 ENERGY STAR Most Efficient Eligible

Taylors Window and Screen, Inc. — 1800/1830 RR/NC Picture Window · Picture Window

Taylors Window and Screen, Inc. engineered the 1800/1830 RR/NC Picture Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 12 glass-spacer combinations from 0.22 to 0.26 U-Factor and 0.19 to 0.23 SHGC. Relative to other Vinyl models tracked under NFRC TWS, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.22
SHGC Range
0.19-0.23
Certified Options
12
Category Standing
#831 of 1,352

How does Taylors Window and Screen, Inc. 1800/1830 RR/NC Picture Window compare thermally against Window peers?

Taylors Window and Screen, Inc. 1800/1830 RR/NC Picture Window achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1800/1830 RR/NC Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 1800/1830 RR/NC Picture Window (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1800/1830 RR/NC Picture Window Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Taylors Window and Screen, Inc. 1800/1830 RR/NC Picture Window standing at #831 of 1,352 certified Window product series, tied with 104 others at 0.22, more insulating than 30.8% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.03 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. 4 configurations meet ENERGY STAR Most Efficient criteria while 4 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-02-23 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 132.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 12 certified glazing combinations for 1800/1830 RR/NC Picture Window (NFRC TWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 4 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 4 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 12 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 12 packages (4 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Taylors Window and Screen, Inc. produce?

Compare other active Taylors Window and Screen, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Taylors Window and Screen, Inc. 1800/1830 RR/NC Picture Window appear below.

How well does 1800/1830 RR/NC Picture Window by Taylors Window and Screen, Inc. insulate relative to Window benchmarks?

Across 12 tested NFRC glazing configurations, Taylors Window and Screen, Inc. 1800/1830 RR/NC Picture Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.22 minimum U-Factor and 0.19-0.23 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.

Is 1800/1830 RR/NC Picture Window approved for Northern Zone heating climates?

Cold-climate buyers get 4 compliant Northern packages inside 1800/1830 RR/NC Picture Window, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.26 options.

How do you calculate winter heat conduction for Taylors Window and Screen, Inc. 1800/1830 RR/NC Picture Window?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.22 U-Factor yields 132.0 BTU/hr conductive transfer (+0.0% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Taylors Window and Screen, Inc. 1800/1830 RR/NC Picture Window and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1800/1830 RR/NC Picture Window options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Taylors Window and Screen, Inc. 1800/1830 RR/NC Picture Window in Southern or South-Central zones?

Warm-climate homeowners have 12 Southern-approved options within 1800/1830 RR/NC Picture Window spanning SHGC down to 0.19. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

How many Taylors Window and Screen, Inc. 1800/1830 RR/NC Picture Window variants earn ENERGY STAR Most Efficient?

Not every package qualifies: 4 of 12 1800/1830 RR/NC Picture Window glazing builds earn Most Efficient recognition (33.3%), while other variants sit on the standard Version 7.0 tier.

Can homeowners claim Form 5695 credits on Taylors Window and Screen, Inc. 1800/1830 RR/NC Picture Window in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify 1800/1830 RR/NC Picture Window after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code TWS and product line TWS-K-12, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Taylors Window and Screen, Inc. 1800/1830 RR/NC Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros