Skip to main content
Window · Vinyl Frame NFRC THG · Product Line THG-K-24

Thermal-Gard Building Products, Inc. — 507/557/607/657 Horizontal Slider · Double Slider

With a minimum U-Factor of 0.22—+0.02 compared against the 0.20 Window median—Thermal-Gard Building Products, Inc. 507/557/607/657 Horizontal Slider spans 4 tested options across Northern, North-Central, South-Central, Southern up to 0.25 U-Factor. Carrying NFRC CPD code THG, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.22 and 0.25.

Min U-Factor
0.22
SHGC Range
0.22-0.25
Certified Options
4
Category Standing
#831 of 1,352

How does Thermal-Gard Building Products, Inc. 507/557/607/657 Horizontal Slider compare thermally against Window peers?

Thermal-Gard Building Products, Inc. 507/557/607/657 Horizontal Slider achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 507/557/607/657 Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 507/557/607/657 Horizontal Slider (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

507/557/607/657 Horizontal Slider Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Thermal-Gard Building Products, Inc. 507/557/607/657 Horizontal Slider standing at #831 of 1,352 certified Window product series, tied with 104 others at 0.22, more insulating than 30.8% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.03 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.22 to 0.25) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 1 combination qualify in the Northern Zone alongside 2 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Data provenance links certification 2025-08-20 and FENSTAR license 2024-08-12 inside EPA Version 7.0 tables. Heat transfer computes to 132.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4 certified glazing combinations for 507/557/607/657 Horizontal Slider (NFRC THG) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 1 package (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 4 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 2 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Thermal-Gard Building Products, Inc. produce?

Compare other active Thermal-Gard Building Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thermal-Gard Building Products, Inc. 507/557/607/657 Horizontal Slider appear below.

What U-Factor and SHGC range does Thermal-Gard Building Products, Inc. 507/557/607/657 Horizontal Slider achieve?

Across 4 tested NFRC glazing configurations, Thermal-Gard Building Products, Inc. 507/557/607/657 Horizontal Slider with Vinyl framing and Dual-Slide Horizontal (HSXX) style reaches a 0.22 minimum U-Factor and 0.22-0.25 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.

How does Thermal-Gard Building Products, Inc. 507/557/607/657 Horizontal Slider satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 1 507/557/607/657 Horizontal Slider package (U floor 0.22, SHGC >= 0.17). Because the complete series stretches up to U 0.25, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from 507/557/607/657 Horizontal Slider's 0.22 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 132.0 BTU/hr on 507/557/607/657 Horizontal Slider's lowest-U package (0.22), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.25 transfer proportionally more energy.

What homeowner profiles are a poor match for Thermal-Gard Building Products, Inc. 507/557/607/657 Horizontal Slider?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 507/557/607/657 Horizontal Slider options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does 507/557/607/657 Horizontal Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 2 Southern-certified options inside Thermal-Gard Building Products, Inc. 507/557/607/657 Horizontal Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.25 SHGC on west-facing glass to avoid excess afternoon solar gain.

How many Thermal-Gard Building Products, Inc. 507/557/607/657 Horizontal Slider variants earn ENERGY STAR Most Efficient?

No. Zero of the 4 configurations in Thermal-Gard Building Products, Inc. 507/557/607/657 Horizontal Slider hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What 2026 federal tax credit and Lead RRP rules apply to 507/557/607/657 Horizontal Slider?

Any 507/557/607/657 Horizontal Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify 507/557/607/657 Horizontal Slider glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.22-0.25, SHGC 0.22-0.25) against permit drawings for line THG-K-24. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Thermal-Gard Building Products, Inc. 507/557/607/657 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros