Skip to main content
Door · Vinyl Frame NFRC THG · Product Line THG-K-21

Thermal-Gard Building Products, Inc. — 592/692 Patio Door · Sliding Patio Door

EPA ENERGY STAR Version 7.0 certifies 2 variants inside Thermal-Gard Building Products, Inc. 592/692 Patio Door, combining Vinyl frame construction with U-Factors spanning 0.24 to 0.25 and SHGC 0.23 to 0.26. Qualifying for Northern, North-Central, South-Central, Southern, this Sliding Patio Door family places #199 of 268 among 268 Door families and posts 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.24
SHGC Range
0.23-0.26
Certified Options
2
Category Standing
#199 of 268

How does Thermal-Gard Building Products, Inc. 592/692 Patio Door compare thermally against Door peers?

Thermal-Gard Building Products, Inc. 592/692 Patio Door achieves a 0.24 thermal floor across Door lines, placing #199 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. 592/692 Patio DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 592/692 Patio Door (U 0.24).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

592/692 Patio Door Cohort StandingMin U-Factor 0.24 stands at rank #199 of 268, outperforming 19.8% of peers.Min U-Factor 0.24Rank #199 of 268 (19.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 268 ENERGY STAR v7.0 Door lines places Thermal-Gard Building Products, Inc. 592/692 Patio Door at rank #199 of 268 (tied with 16 others at 0.24, more insulating than 19.8% of Door lines; cohort median 0.21). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.23-0.26 band.

Mapping NFRC SHGC values (0.23 to 0.26) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 2 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors THG to 2024-09-18 certification (FENSTAR issued 2024-08-12). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2 certified glazing combinations for 592/692 Patio Door (NFRC THG) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 2 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 2 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1 package (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1 package (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Thermal-Gard Building Products, Inc. produce?

Compare other active Thermal-Gard Building Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thermal-Gard Building Products, Inc. 592/692 Patio Door appear below.

How well does 592/692 Patio Door by Thermal-Gard Building Products, Inc. insulate relative to Door benchmarks?

Built with Vinyl framing in Sliding Glass Door (DDSG) style, Thermal-Gard Building Products, Inc. 592/692 Patio Door offers 2 Version 7.0 configurations from U 0.24 up to 0.25, posting +0.03 against the Door median of 0.21 with 0 Most Efficient picks.

How does Thermal-Gard Building Products, Inc. 592/692 Patio Door satisfy Version 7.0 Northern criteria?

Northern qualification on 592/692 Patio Door relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 2 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

What conductive BTU/hr difference separates 592/692 Patio Door from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.24 U-Factor yields 144.0 BTU/hr conductive transfer (+9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Thermal-Gard Building Products, Inc. 592/692 Patio Door?

Do not specify 592/692 Patio Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 592/692 Patio Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is 592/692 Patio Door suitable for sunbelt cooling-dominated homes?

Yes, 592/692 Patio Door holds 1 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.23 SHGC in cooling climates.

Which package tier in 592/692 Patio Door holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 2 592/692 Patio Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

Can homeowners claim Form 5695 credits on Thermal-Gard Building Products, Inc. 592/692 Patio Door in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 592/692 Patio Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on 592/692 Patio Door?

Verify NFRC ID THG and series THG-K-21 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Thermal-Gard Building Products, Inc. 592/692 Patio Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros