Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.21 across 4 certified glazing configurations covering Northern, North-Central. Ranked #742 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.24 to 0.27.

Min U-Factor
0.21
SHGC Range
0.24-0.27
Certified Options
4
Category Standing
#742 of 1,352

How does Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window compare thermally against Window peers?

Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 501/551/601/651 Single Hung Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 501/551/601/651 Single Hung Picture Window (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

501/551/601/651 Single Hung Picture Window Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window at rank #742 of 1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.24-0.27 band.

Zone eligibility across EPA boundaries reaches 2 markets (Northern, North-Central). 2 combinations qualify in the Northern Zone alongside 0 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2024-08-12 and v7.0 data certification on 2025-08-20. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.21 conducts 126.0 BTU/hr (-6.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4 certified glazing combinations for 501/551/601/651 Single Hung Picture Window (NFRC THG) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 2 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 4 packages (0 Most Eff.)
South-Central Not Listed <= 0.28 <= 0.23 0 packages (0 Most Eff.)
Southern Not Listed <= 0.32 <= 0.23 0 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Thermal-Gard Building Products, Inc. produce?

Compare other active Thermal-Gard Building Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window appear below.

How well does 501/551/601/651 Single Hung Picture Window by Thermal-Gard Building Products, Inc. insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 4 configurations for Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window covering Northern, North-Central, dropping down to U 0.21 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window qualify for the ENERGY STAR Northern Zone?

Yes, 2 packages satisfy Northern ENERGY STAR Version 7.0 rules in 501/551/601/651 Single Hung Picture Window. Pairing multi-pane insulation down to 0.21 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What conductive BTU/hr difference separates 501/551/601/651 Single Hung Picture Window from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 501/551/601/651 Single Hung Picture Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Is 501/551/601/651 Single Hung Picture Window suitable for sunbelt cooling-dominated homes?

Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window carries zero Southern Zone approvals (0 options; SHGC 0.24-0.27). Cooling-dominated sunbelt homes should look at peer lines certified to SHGC <= 0.23.

Are all 4 501/551/601/651 Single Hung Picture Window configurations ENERGY STAR Most Efficient?

501/551/601/651 Single Hung Picture Window holds zero Most Efficient entries across its 4 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Do 2026 501/551/601/651 Single Hung Picture Window installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 501/551/601/651 Single Hung Picture Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify 501/551/601/651 Single Hung Picture Window after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line THG-K-22 and NFRC ID THG before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros