Skip to main content
Window · Vinyl Frame NFRC KOI · Product Line KOI-A-87 ENERGY STAR Most Efficient Eligible

Kohltech International, Ltd. — Supreme Single Hung · Single Hung

Positioning #742/1,352 in certified Window, Kohltech International, Ltd. Supreme Single Hung pairs Vinyl frame construction with 15 glazing options rated between 0.21 and 0.50 SHGC across Northern, North-Central, South-Central, Southern. Across 21 certified Kohltech International, Ltd. product families, its thermal resistance spans 0.21 to 0.26 U-Factor and the line includes 2 ENERGY STAR Most Efficient packages (13.3% of line).

Min U-Factor
0.21
SHGC Range
0.21-0.50
Certified Options
15
Category Standing
#742 of 1,352

How does Kohltech International, Ltd. Supreme Single Hung compare thermally against Window peers?

Kohltech International, Ltd. Supreme Single Hung achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Supreme Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Supreme Single Hung (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Supreme Single Hung Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Supreme Single Hung spans 15 NFRC test records (KOI), ranking #742 of 1,352 Window families (tied with 88 others at 0.21, more insulating than 38.6% of Window lines). Its 0.21 thermal floor compares at +0.02 against the Vinyl median (0.19).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 2 configurations meet ENERGY STAR Most Efficient criteria while 12 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors KOI to 2025-05-16 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 126.0 BTU/hr conductive loss (-4.5% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 15 certified glazing combinations for Supreme Single Hung (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 12 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 7 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 3 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 3 packages (2 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kohltech International, Ltd. produce?

Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. Supreme Single Hung appear below.

How efficient is Kohltech International, Ltd. Supreme Single Hung compared with peer Window models?

Built with Vinyl framing in Single-Hung (VSSH) style, Kohltech International, Ltd. Supreme Single Hung offers 15 Version 7.0 configurations from U 0.21 up to 0.26, posting +0.01 against the Window median of 0.20 with 2 Most Efficient picks.

Which glazing options in Kohltech International, Ltd. Supreme Single Hung meet Northern climate limits?

Yes, 12 packages satisfy Northern ENERGY STAR Version 7.0 rules in Supreme Single Hung. Pairing multi-pane insulation down to 0.21 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How much winter heat loss does Supreme Single Hung conduct across a 15 sq ft opening?

At U 0.21, a standard 3x5 ft (15 sq ft) Supreme Single Hung opening transfers 126.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -6.0 BTU/hr difference.

What are the practical limitations of specifying Supreme Single Hung?

Skip Supreme Single Hung if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Supreme Single Hung options exceeding U 0.22.

How many Supreme Single Hung glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 3 Southern-approved options within Supreme Single Hung spanning SHGC down to 0.21. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in Supreme Single Hung holds Most Efficient recognition?

Within Supreme Single Hung, 13.3% (2 of 15) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect Supreme Single Hung?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Supreme Single Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on Supreme Single Hung?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code KOI and product line KOI-A-87, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. Supreme Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros