Skip to main content
Window · Vinyl Frame NFRC KOI · Product Line KOI-A-92 ENERGY STAR Most Efficient Eligible

Kohltech International, Ltd. — 2020 Supreme Casement · Casement Windows

With a minimum U-Factor of 0.15—-0.05 compared against the 0.20 Window median—Kohltech International, Ltd. 2020 Supreme Casement spans 31 tested options across Northern, North-Central, South-Central, Southern up to 0.26 U-Factor. Carrying NFRC CPD code KOI, the Vinyl assembly includes 14 ENERGY STAR Most Efficient packages (45.2% of line) and offers SHGC packages between 0.19 and 0.52.

Min U-Factor
0.15
SHGC Range
0.19-0.52
Certified Options
31
Category Standing
#136 of 1,352

How does Kohltech International, Ltd. 2020 Supreme Casement compare thermally against Window peers?

Kohltech International, Ltd. 2020 Supreme Casement achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 2020 Supreme CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 2020 Supreme Casement (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

2020 Supreme Casement Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 2020 Supreme Casement spans 31 NFRC test records (KOI), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.04 against the Vinyl median (0.19).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 14 configurations meet ENERGY STAR Most Efficient criteria while 22 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 90.0 BTU/hr (-31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2025-05-16.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 31 certified glazing combinations for 2020 Supreme Casement (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 22 packages (13 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 18 packages (10 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 7 packages (4 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 7 packages (4 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
DRUTEX S.A. — IGLO EDGE Fixed Window Vinyl 0.15 0.21 26
OKNA Windows & Doors Mfg — 410 Picture Window Vinyl 0.15 0.16 56
Vector Windows — Envision Casement Picture Vinyl 0.15 0.18 57
OKNA Windows & Doors Mfg — 7500 Double Hung Vinyl 0.15 0.15 59
Mathews Brothers Company — Sanford Hills Fixed Casement Vinyl 0.15 0.24 64

What other certified series does Kohltech International, Ltd. produce?

Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. 2020 Supreme Casement appear below.

What U-Factor and SHGC range does Kohltech International, Ltd. 2020 Supreme Casement achieve?

Built with Vinyl framing in Casement Single-Vent (CSSV) style, Kohltech International, Ltd. 2020 Supreme Casement offers 31 Version 7.0 configurations from U 0.15 up to 0.26, posting -0.05 against the Window median of 0.20 with 14 Most Efficient picks.

Can homeowners install 2020 Supreme Casement in cold Northern ENERGY STAR counties?

Kohltech International, Ltd. 2020 Supreme Casement supplies 22 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.26, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for Kohltech International, Ltd. 2020 Supreme Casement?

Using NFRC KOI U-Factor 0.15, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).

What homeowner profiles are a poor match for Kohltech International, Ltd. 2020 Supreme Casement?

Skip 2020 Supreme Casement if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 2020 Supreme Casement options exceeding U 0.22.

Does 2020 Supreme Casement meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 7 Southern-certified options inside Kohltech International, Ltd. 2020 Supreme Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.52 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does 2020 Supreme Casement carry EPA Most Efficient certification across its lineup?

EPA lists 14 Most Efficient options (45.2% share) inside Kohltech International, Ltd. 2020 Supreme Casement, out of 31 total Version 7.0 entries.

How do the 25C sunset and pre-1978 Lead RRP rules affect 2020 Supreme Casement?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Kohltech International, Ltd. 2020 Supreme Casement units match permits?

Inspectors match the temporary NFRC sticker (U 0.15-0.26, SHGC 0.19-0.52) against permit drawings for line KOI-A-92. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. 2020 Supreme Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros