Skip to main content
Window · Vinyl Frame NFRC KOI · Product Line KOI-A-94 ENERGY STAR Most Efficient Eligible

Kohltech International, Ltd. — 2020 Supreme Wide Picture · Picture Window

Kohltech International, Ltd. engineered the 2020 Supreme Wide Picture Picture Window line for Northern, North-Central, South-Central, Southern, certifying 24 glass-spacer combinations from 0.15 to 0.25 U-Factor and 0.22 to 0.52 SHGC. Relative to other Vinyl models tracked under NFRC KOI, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.15
SHGC Range
0.22-0.52
Certified Options
24
Category Standing
#136 of 1,352

How does Kohltech International, Ltd. 2020 Supreme Wide Picture compare thermally against Window peers?

Kohltech International, Ltd. 2020 Supreme Wide Picture achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 2020 Supreme Wide PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 2020 Supreme Wide Picture (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

2020 Supreme Wide Picture Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 2020 Supreme Wide Picture spans 24 NFRC test records (KOI), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.04 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.22 to 0.52) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 14 configurations meet ENERGY STAR Most Efficient criteria while 16 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-02-10 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 90.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 24 certified glazing combinations for 2020 Supreme Wide Picture (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 16 packages (14 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 16 packages (8 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1 package (1 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1 package (1 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
DRUTEX S.A. — IGLO EDGE Fixed Window Vinyl 0.15 0.21 26
OKNA Windows & Doors Mfg — 410 Picture Window Vinyl 0.15 0.16 56
Vector Windows — Envision Casement Picture Vinyl 0.15 0.18 57
OKNA Windows & Doors Mfg — 7500 Double Hung Vinyl 0.15 0.15 59
Mathews Brothers Company — Sanford Hills Fixed Casement Vinyl 0.15 0.24 64

What other certified series does Kohltech International, Ltd. produce?

Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. 2020 Supreme Wide Picture appear below.

What U-Factor and SHGC range does Kohltech International, Ltd. 2020 Supreme Wide Picture achieve?

Kohltech International, Ltd. 2020 Supreme Wide Picture spans 24 certified configurations with U-Factors between 0.15 and 0.25 and SHGC values from 0.22 to 0.52. Ranked #136 of 1,352 Window families, it carries 14 Most Efficient options.

How does Kohltech International, Ltd. 2020 Supreme Wide Picture satisfy Version 7.0 Northern criteria?

Yes, 16 packages satisfy Northern ENERGY STAR Version 7.0 rules in 2020 Supreme Wide Picture. Pairing multi-pane insulation down to 0.15 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How do you calculate winter heat conduction for Kohltech International, Ltd. 2020 Supreme Wide Picture?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 90.0 BTU/hr on 2020 Supreme Wide Picture's lowest-U package (0.15), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.25 transfer proportionally more energy.

What homeowner profiles are a poor match for Kohltech International, Ltd. 2020 Supreme Wide Picture?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 2020 Supreme Wide Picture options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in 2020 Supreme Wide Picture?

Exactly 1 2020 Supreme Wide Picture option qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.22 rather than higher 0.52 glass.

Does 2020 Supreme Wide Picture carry EPA Most Efficient certification across its lineup?

No. Exactly 14 of 24 configurations (58.3%) earn ENERGY STAR Most Efficient status in 2020 Supreme Wide Picture; the remaining standard v7.0 options pass base zone limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect 2020 Supreme Wide Picture?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 2020 Supreme Wide Picture installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered Kohltech International, Ltd. 2020 Supreme Wide Picture units match permits?

Verify NFRC ID KOI and series KOI-A-94 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. 2020 Supreme Wide Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros