Skip to main content
Window · Vinyl Frame NFRC KOI · Product Line KOI-A-95 ENERGY STAR Most Efficient Eligible

Kohltech International, Ltd. — 2020 Supreme Awning · Awning (Projected)

With a minimum U-Factor of 0.15—-0.05 compared against the 0.20 Window median—Kohltech International, Ltd. 2020 Supreme Awning spans 29 tested options across Northern, North-Central, South-Central, Southern up to 0.26 U-Factor. Carrying NFRC CPD code KOI, the Vinyl assembly includes 14 ENERGY STAR Most Efficient packages (48.3% of line) and offers SHGC packages between 0.19 and 0.52.

Min U-Factor
0.15
SHGC Range
0.19-0.52
Certified Options
29
Category Standing
#136 of 1,352

How does Kohltech International, Ltd. 2020 Supreme Awning compare thermally against Window peers?

Kohltech International, Ltd. 2020 Supreme Awning achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 2020 Supreme AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 2020 Supreme Awning (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

2020 Supreme Awning Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Kohltech International, Ltd. 2020 Supreme Awning standing at #136 of 1,352 certified Window product series, tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%. Comparing Vinyl profiles alone (median 0.19) shows -0.04 before selecting Low-E tiers.

Climate coverage for Kohltech International, Ltd. 2020 Supreme Awning spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 14 configurations meet ENERGY STAR Most Efficient criteria while 20 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-02-10. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 29 certified glazing combinations for 2020 Supreme Awning (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 20 packages (13 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 18 packages (10 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 7 packages (4 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 7 packages (4 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
DRUTEX S.A. — IGLO EDGE Fixed Window Vinyl 0.15 0.21 26
OKNA Windows & Doors Mfg — 410 Picture Window Vinyl 0.15 0.16 56
Vector Windows — Envision Casement Picture Vinyl 0.15 0.18 57
OKNA Windows & Doors Mfg — 7500 Double Hung Vinyl 0.15 0.15 59
Mathews Brothers Company — Sanford Hills Fixed Casement Vinyl 0.15 0.24 64

What other certified series does Kohltech International, Ltd. produce?

Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. 2020 Supreme Awning appear below.

What U-Factor and SHGC range does Kohltech International, Ltd. 2020 Supreme Awning achieve?

Across 29 tested NFRC glazing configurations, Kohltech International, Ltd. 2020 Supreme Awning with Vinyl framing and Projected Awning (PRAW) style reaches a 0.15 minimum U-Factor and 0.19-0.52 SHGC band. It places #136 among 1,352 Window series—top 18.4%.

Is 2020 Supreme Awning approved for Northern Zone heating climates?

Yes, 20 packages satisfy Northern ENERGY STAR Version 7.0 rules in 2020 Supreme Awning. Pairing multi-pane insulation down to 0.15 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What conductive BTU/hr difference separates 2020 Supreme Awning from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 2020 Supreme Awning at U 0.15 conducts 90.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make 2020 Supreme Awning the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 2020 Supreme Awning options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Kohltech International, Ltd. 2020 Supreme Awning in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 7 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Kohltech International, Ltd. 2020 Supreme Awning, while total line SHGC reaches 0.52 in colder packages.

Does 2020 Supreme Awning carry EPA Most Efficient certification across its lineup?

EPA lists 14 Most Efficient options (48.3% share) inside Kohltech International, Ltd. 2020 Supreme Awning, out of 29 total Version 7.0 entries.

How do the 25C sunset and pre-1978 Lead RRP rules affect 2020 Supreme Awning?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 2020 Supreme Awning installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC KOI and product line KOI-A-95 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code KOI and product line KOI-A-95, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. 2020 Supreme Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)