Thermal-Gard Building Products, Inc. — 851/951 Casement Picture Window · Picture Window
Thermal-Gard Building Products, Inc. 851/951 Casement Picture Window is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.21 across 8 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #742 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.23 to 0.29.
- Min U-Factor
- 0.21
- SHGC Range
- 0.23-0.29
- Certified Options
- 8
- Category Standing
- #742 of 1,352
How does Thermal-Gard Building Products, Inc. 851/951 Casement Picture Window compare thermally against Window peers?
Thermal-Gard Building Products, Inc. 851/951 Casement Picture Window achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), 851/951 Casement Picture Window is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.21-0.25.
Climate coverage for Thermal-Gard Building Products, Inc. 851/951 Casement Picture Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 1 configuration meet ENERGY STAR Most Efficient criteria while 4 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2024-09-18 and FENSTAR license 2024-08-12 inside EPA Version 7.0 tables. Heat transfer computes to 126.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 8 certified glazing combinations for 851/951 Casement Picture Window (NFRC THG) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 4 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 8 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 3 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 3 packages (1 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| DRUTEX S.A. — IGLO LIGHT Casement | Vinyl | 0.21 | 0.17 | 5 |
| DRUTEX S.A. — IGLO LIGHT Transom (Awning) | Vinyl | 0.21 | 0.17 | 5 |
| Kohltech International, Ltd. — Supreme Single Glider | Vinyl | 0.21 | 0.21 | 11 |
| Energy King Windows & Doors Inc. — Pro Series Horizontal Slider | Vinyl | 0.21 | 0.22 | 12 |
| Kohltech International, Ltd. — Supreme Single Hung | Vinyl | 0.21 | 0.21 | 15 |
What other certified series does Thermal-Gard Building Products, Inc. produce?
Compare other active Thermal-Gard Building Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
501/551/601/651 Single Hung Picture Window
U-Factor 0.21–0.24 · 4 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thermal-Gard Building Products, Inc. 851/951 Casement Picture Window appear below.
What thermal performance numbers separate Thermal-Gard Building Products, Inc. 851/951 Casement Picture Window from peers?
Across 8 tested NFRC glazing configurations, Thermal-Gard Building Products, Inc. 851/951 Casement Picture Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.21 minimum U-Factor and 0.23-0.29 SHGC band. It places #742 among 1,352 Window series—more insulating than 38.6%.
Does Thermal-Gard Building Products, Inc. 851/951 Casement Picture Window qualify for the ENERGY STAR Northern Zone?
Yes. 4 packages in Thermal-Gard Building Products, Inc. 851/951 Casement Picture Window clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.25.
How does a 3x5 ft 851/951 Casement Picture Window window perform under a 40 deg F temperature drop?
Using NFRC THG U-Factor 0.21, a 15 sq ft Fixed Window (FIXD) assembly conducts 126.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-6.0 BTU/hr margin).
What homeowner profiles are a poor match for Thermal-Gard Building Products, Inc. 851/951 Casement Picture Window?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 851/951 Casement Picture Window options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Is 851/951 Casement Picture Window suitable for sunbelt cooling-dominated homes?
Exactly 3 851/951 Casement Picture Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.23 rather than higher 0.29 glass.
Does 851/951 Casement Picture Window carry EPA Most Efficient certification across its lineup?
Within 851/951 Casement Picture Window, 12.5% (1 of 8) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
How do the 25C sunset and pre-1978 Lead RRP rules affect 851/951 Casement Picture Window?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 851/951 Casement Picture Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
Where are NFRC and IGCC identification marks located on 851/951 Casement Picture Window?
Confirm both the paper NFRC label and permanent corner glass etch match line THG-K-18 and NFRC ID THG before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Thermal-Gard Building Products, Inc. 851/951 Casement Picture Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)