Skip to main content
Window · Vinyl Frame NFRC DRU · Product Line DRU-K-47

DRUTEX S.A. — IGLO LIGHT Transom (Awning) · Awning (Projected)

DRUTEX S.A. IGLO LIGHT Transom (Awning) is a Awning, Projected assembly with a Vinyl frame that reaches a minimum U-Factor of 0.21 across 5 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #742 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.17 to 0.29.

Min U-Factor
0.21
SHGC Range
0.17-0.29
Certified Options
5
Category Standing
#742 of 1,352

How does DRUTEX S.A. IGLO LIGHT Transom (Awning) compare thermally against Window peers?

DRUTEX S.A. IGLO LIGHT Transom (Awning) achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. IGLO LIGHT Transom (Awning)Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing IGLO LIGHT Transom (Awning) (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

IGLO LIGHT Transom (Awning) Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), IGLO LIGHT Transom (Awning) reaches 0.21 on its lowest-conductivity package — #561 of 1,009 in Vinyl, tied with 78 others at 0.21, more insulating than 36.7% of Vinyl lines (+0.02 vs Vinyl peers). Pairing NFRC ID DRU across multi-pane fills shifts U-Factor from 0.28 down toward 0.21.

Mapping NFRC SHGC values (0.17 to 0.29) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 2 combinations qualify in the Northern Zone alongside 2 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2023-04-03 and cert timestamp 2025-07-10.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 5 certified glazing combinations for IGLO LIGHT Transom (Awning) (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 2 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 3 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 2 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO LIGHT Transom (Awning) appear below.

How well does IGLO LIGHT Transom (Awning) by DRUTEX S.A. insulate relative to Window benchmarks?

Built with Vinyl framing in Projected Awning (PRAW) style, DRUTEX S.A. IGLO LIGHT Transom (Awning) offers 5 Version 7.0 configurations from U 0.21 up to 0.28, posting +0.01 against the Window median of 0.20 with 0 Most Efficient picks.

Is IGLO LIGHT Transom (Awning) approved for Northern Zone heating climates?

Cold-climate buyers get 2 compliant Northern packages inside IGLO LIGHT Transom (Awning), reaching down to U 0.21. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

How much winter heat loss does IGLO LIGHT Transom (Awning) conduct across a 15 sq ft opening?

Using NFRC DRU U-Factor 0.21, a 15 sq ft Projected Awning (PRAW) assembly conducts 126.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-6.0 BTU/hr margin).

Which situations make IGLO LIGHT Transom (Awning) the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO LIGHT Transom (Awning) options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Can you install DRUTEX S.A. IGLO LIGHT Transom (Awning) in Southern or South-Central zones?

Yes. 2 Southern-certified options inside DRUTEX S.A. IGLO LIGHT Transom (Awning) satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.29 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside IGLO LIGHT Transom (Awning) qualifies as Most Efficient?

All 5 IGLO LIGHT Transom (Awning) listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What federal compliance checks govern 2026 IGLO LIGHT Transom (Awning) window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 DRUTEX S.A. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

Where are NFRC and IGCC identification marks located on IGLO LIGHT Transom (Awning)?

Inspectors match the temporary NFRC sticker (U 0.21-0.28, SHGC 0.17-0.29) against permit drawings for line DRU-K-47. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO LIGHT Transom (Awning) come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros