Skip to main content
Window · Vinyl Frame NFRC KOI · Product Line KOI-A-86 ENERGY STAR Most Efficient Eligible

Kohltech International, Ltd. — Supreme Single Glider · Single Slider

EPA ENERGY STAR Version 7.0 certifies 11 variants inside Kohltech International, Ltd. Supreme Single Glider, combining Vinyl frame construction with U-Factors spanning 0.21 to 0.25 and SHGC 0.21 to 0.48. Qualifying for Northern, North-Central, South-Central, Southern, this Single Slider family places #742 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.21
SHGC Range
0.21-0.48
Certified Options
11
Category Standing
#742 of 1,352

How does Kohltech International, Ltd. Supreme Single Glider compare thermally against Window peers?

Kohltech International, Ltd. Supreme Single Glider achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Supreme Single GliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Supreme Single Glider (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Supreme Single Glider Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Supreme Single Glider is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.21-0.25.

Mapping NFRC SHGC values (0.21 to 0.48) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 2 configurations meet ENERGY STAR Most Efficient criteria while 10 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.21 U-Factor yields 126.0 BTU/hr transfer (-6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2025-07-24 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 11 certified glazing combinations for Supreme Single Glider (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 10 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 5 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 3 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 3 packages (2 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kohltech International, Ltd. produce?

Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. Supreme Single Glider appear below.

What U-Factor and SHGC range does Kohltech International, Ltd. Supreme Single Glider achieve?

EPA ENERGY STAR v7.0 records 11 configurations for Kohltech International, Ltd. Supreme Single Glider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.21 versus a 0.20 Window median. Only 2 options earn Most Efficient status.

Which glazing options in Kohltech International, Ltd. Supreme Single Glider meet Northern climate limits?

Cold-climate buyers get 10 compliant Northern packages inside Supreme Single Glider, reaching down to U 0.21. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.25 options.

How does a 3x5 ft Supreme Single Glider window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Kohltech International, Ltd. Supreme Single Glider?

Skip Supreme Single Glider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Supreme Single Glider options exceeding U 0.22.

Does Supreme Single Glider meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, Supreme Single Glider holds 3 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.21 SHGC in cooling climates.

Are all 11 Supreme Single Glider configurations ENERGY STAR Most Efficient?

No. Exactly 2 of 11 configurations (18.2%) earn ENERGY STAR Most Efficient status in Supreme Single Glider; the remaining standard v7.0 options pass base zone limits only.

What federal compliance checks govern 2026 Supreme Single Glider window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Kohltech International, Ltd. Supreme Single Glider units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line KOI-A-86 and NFRC ID KOI before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. Supreme Single Glider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros