Thermal-Gard Building Products, Inc. — 505/555/605/655 Double Hung · Double Hung
Thermal-Gard Building Products, Inc. engineered the 505/555/605/655 Double Hung Double Hung line for Northern, North-Central, South-Central, Southern, certifying 16 glass-spacer combinations from 0.22 to 0.26 U-Factor and 0.22 to 0.24 SHGC. Relative to other Vinyl models tracked under NFRC THG, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.22
- SHGC Range
- 0.22-0.24
- Certified Options
- 16
- Category Standing
- #831 of 1,352
How does Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung compare thermally against Window peers?
Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung at rank #831 of 1,352 (tied with 104 others at 0.22, more insulating than 30.8% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.22-0.24 band.
Regional qualification covers Northern, North-Central, South-Central, Southern. 6 combinations qualify in the Northern Zone alongside 9 Southern configurations matching hot-climate SHGC <= 0.23 caps.
Registry history records EPA FENSTAR licensing on 2024-08-12 and v7.0 data certification on 2024-09-18. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.22 conducts 132.0 BTU/hr (matching the 0.22 Northern baseline).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 16 certified glazing combinations for 505/555/605/655 Double Hung (NFRC THG) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 6 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 13 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 9 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 9 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Advent Windows and Doors — Ascend Series PW | Vinyl | 0.22 | 0.14 | 16 |
| Taylors Window and Screen, Inc. — 7000/8000 Series Picture Window | Vinyl | 0.22 | 0.19 | 14 |
| Energy King Windows & Doors Inc. — Pro Series Double Hung | Vinyl | 0.22 | 0.22 | 12 |
| Taylors Window and Screen, Inc. — 1800/1830 RR/NC Picture Window | Vinyl | 0.22 | 0.19 | 12 |
| California Deluxe Windows Industries, Inc. — S-6300 Tilt & Turn Window | Vinyl | 0.22 | 0.13 | 22 |
What other certified series does Thermal-Gard Building Products, Inc. produce?
Compare other active Thermal-Gard Building Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
501/551/601/651 Single Hung Picture Window
U-Factor 0.21–0.24 · 4 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung appear below.
Where does Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung stand thermally among ENERGY STAR Window lines?
Across 16 tested NFRC glazing configurations, Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung with Vinyl framing and Double-Hung (VSDH) style reaches a 0.22 minimum U-Factor and 0.22-0.24 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.
Which glazing options in Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung meet Northern climate limits?
Cold-climate buyers get 6 compliant Northern packages inside 505/555/605/655 Double Hung, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.26 options.
What conductive BTU/hr difference separates 505/555/605/655 Double Hung from the 0.22 Northern rule?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 505/555/605/655 Double Hung at U 0.22 conducts 132.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What are the practical limitations of specifying 505/555/605/655 Double Hung?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 505/555/605/655 Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.
Is 505/555/605/655 Double Hung suitable for sunbelt cooling-dominated homes?
Yes, 505/555/605/655 Double Hung holds 9 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.22 SHGC in cooling climates.
How many Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung variants earn ENERGY STAR Most Efficient?
ENERGY STAR Most Efficient designation is absent across all 16 505/555/605/655 Double Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
What federal compliance checks govern 2026 505/555/605/655 Double Hung window swaps?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How can homeowners confirm delivered Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung units match permits?
Confirm both the paper NFRC label and permanent corner glass etch match line THG-K-20 and NFRC ID THG before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)