Taylors Window and Screen, Inc. — 8501 NC/Repl Casement Picture Window · Picture Window
Taylors Window and Screen, Inc. 8501 NC/Repl Casement Picture Window is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.23 across 18 certified glazing configurations covering North-Central, South-Central, Southern. Ranked #936 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.18 to 0.27.
- Min U-Factor
- 0.23
- SHGC Range
- 0.18-0.27
- Certified Options
- 18
- Category Standing
- #936 of 1,352
How does Taylors Window and Screen, Inc. 8501 NC/Repl Casement Picture Window compare thermally against Window peers?
Taylors Window and Screen, Inc. 8501 NC/Repl Casement Picture Window achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across 8501 NC/Repl Casement Picture Window spans 18 NFRC test records (TWS), ranking #936 of 1,352 Window families (tied with 97 others at 0.23, more insulating than 23.6% of Window lines). Its 0.23 thermal floor compares at +0.04 against the Vinyl median (0.19).
Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.18 lowers cooling load.
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 138.0 BTU/hr (+4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-02-21.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 18 certified glazing combinations for 8501 NC/Repl Casement Picture Window (NFRC TWS) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 8 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 16 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 16 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Morfe Windows LLC — Horizontal Sliding Window | Vinyl | 0.23 | 0.18 | 20 |
| Vytex Corporation — Grandview Horizontal Slider | Vinyl | 0.23 | 0.19 | 21 |
| Vytex Corporation — Grandview Double Hung | Vinyl | 0.23 | 0.19 | 22 |
| California Deluxe Windows Industries, Inc. — S-3480 Single Hung | Vinyl | 0.23 | 0.12 | 28 |
| California Deluxe Windows Industries, Inc. — S-3555 Double Hung | Vinyl | 0.23 | 0.11 | 28 |
What other certified series does Taylors Window and Screen, Inc. produce?
Compare other active Taylors Window and Screen, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
1800/1830 RR/NC OX Horizontal Slider
U-Factor 0.24–0.28 · 12 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Taylors Window and Screen, Inc. 8501 NC/Repl Casement Picture Window appear below.
What U-Factor and SHGC range does Taylors Window and Screen, Inc. 8501 NC/Repl Casement Picture Window achieve?
Taylors Window and Screen, Inc. 8501 NC/Repl Casement Picture Window spans 18 certified configurations with U-Factors between 0.23 and 0.28 and SHGC values from 0.18 to 0.27. Ranked #936 of 1,352 Window families, it carries 0 Most Efficient options.
Is 8501 NC/Repl Casement Picture Window approved for Northern Zone heating climates?
This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.23). Focus on North-Central, South-Central, Southern glazing applications where SHGC 0.18-0.27 manages cooling loads.
How do you calculate winter heat conduction for Taylors Window and Screen, Inc. 8501 NC/Repl Casement Picture Window?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 138.0 BTU/hr on 8501 NC/Repl Casement Picture Window's lowest-U package (0.23), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.
What are the practical limitations of specifying 8501 NC/Repl Casement Picture Window?
Do not specify 8501 NC/Repl Casement Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 8501 NC/Repl Casement Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Is 8501 NC/Repl Casement Picture Window suitable for sunbelt cooling-dominated homes?
Exactly 16 8501 NC/Repl Casement Picture Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.18 rather than higher 0.27 glass.
Does 8501 NC/Repl Casement Picture Window carry EPA Most Efficient certification across its lineup?
No. Zero of the 18 configurations in Taylors Window and Screen, Inc. 8501 NC/Repl Casement Picture Window hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.
What 2026 federal tax credit and Lead RRP rules apply to 8501 NC/Repl Casement Picture Window?
Any 8501 NC/Repl Casement Picture Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How do you cross-check NFRC TWS and product line TWS-K-17 on delivery?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code TWS and product line TWS-K-17, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Taylors Window and Screen, Inc. 8501 NC/Repl Casement Picture Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)