Skip to main content
Window · Vinyl Frame NFRC TWS · Product Line TWS-K-15

Taylors Window and Screen, Inc. — 1800/1830 RR/NC OX Horizontal Slider · Single Slider

Taylors Window and Screen, Inc. engineered the 1800/1830 RR/NC OX Horizontal Slider Single Slider line for North-Central, South-Central, Southern, certifying 12 glass-spacer combinations from 0.24 to 0.28 U-Factor and 0.18 to 0.22 SHGC. Relative to other Vinyl models tracked under NFRC TWS, its minimum U-Factor is 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.18-0.22
Certified Options
12
Category Standing
#1,034 of 1,352

How does Taylors Window and Screen, Inc. 1800/1830 RR/NC OX Horizontal Slider compare thermally against Window peers?

Taylors Window and Screen, Inc. 1800/1830 RR/NC OX Horizontal Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1800/1830 RR/NC OX Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 1800/1830 RR/NC OX Horizontal Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1800/1830 RR/NC OX Horizontal Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 9 certified Taylors Window and Screen, Inc. series, this Single Slider offers a 0.04 U-Factor adjustment span between 0.28 entry options and 0.24 top-performing glazing. Category standing is #1,034/1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines).

Mapping NFRC SHGC values (0.18 to 0.22) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.18 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 144.0 BTU/hr (+9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-02-21.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 12 certified glazing combinations for 1800/1830 RR/NC OX Horizontal Slider (NFRC TWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 4 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 12 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 12 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Taylors Window and Screen, Inc. produce?

Compare other active Taylors Window and Screen, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Taylors Window and Screen, Inc. 1800/1830 RR/NC OX Horizontal Slider appear below.

What U-Factor and SHGC range does Taylors Window and Screen, Inc. 1800/1830 RR/NC OX Horizontal Slider achieve?

EPA ENERGY STAR v7.0 records 12 configurations for Taylors Window and Screen, Inc. 1800/1830 RR/NC OX Horizontal Slider covering North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Can homeowners install 1800/1830 RR/NC OX Horizontal Slider in cold Northern ENERGY STAR counties?

Northern Zone certification is absent for 1800/1830 RR/NC OX Horizontal Slider (0 qualifying options, min U 0.24). Install this Horizontal Slider (HSOX) product only within North-Central, South-Central, Southern regions where lower SHGC caps apply.

How do you calculate winter heat conduction for Taylors Window and Screen, Inc. 1800/1830 RR/NC OX Horizontal Slider?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on 1800/1830 RR/NC OX Horizontal Slider's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

Which situations make 1800/1830 RR/NC OX Horizontal Slider the wrong window or door choice?

Skip 1800/1830 RR/NC OX Horizontal Slider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 1800/1830 RR/NC OX Horizontal Slider options exceeding U 0.22.

How many 1800/1830 RR/NC OX Horizontal Slider glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 12 Southern-approved options within 1800/1830 RR/NC OX Horizontal Slider spanning SHGC down to 0.18. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does 1800/1830 RR/NC OX Horizontal Slider carry EPA Most Efficient certification across its lineup?

1800/1830 RR/NC OX Horizontal Slider holds zero Most Efficient entries across its 12 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

What 2026 federal tax credit and Lead RRP rules apply to 1800/1830 RR/NC OX Horizontal Slider?

Any 1800/1830 RR/NC OX Horizontal Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify 1800/1830 RR/NC OX Horizontal Slider glass specs on job sites?

Verify NFRC ID TWS and series TWS-K-15 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Taylors Window and Screen, Inc. 1800/1830 RR/NC OX Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)